iTHERM ModuLine TM111
Trend-setting, modular thermometer for direct installation into a variety of industrial applications
Easy-to-use metric version with outstanding RTD or TC sensor technology. An optional head transmitter, with all common communication protocols - Bluetooth® technology inclusive, makes the device ready to use with enhanced measurement accuracy and reliability. A variety of process connections, dimensions and materials offer flexible application possibilities. It features vibration-resistant and fast-response sensor technology (iTHERM StrongSens and QuickSens) as well as hazardous area approvals.
- F
- L
- E
- X
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
Specificaţii pe scurt
-
Accuracy
Class AA acc. to IEC 60751
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class special or standard acc. to ASTM E230
Class 1 or 2 acc. to IEC 60584-2 -
Response time
t90 starting at < 1,5 s QuickSens
depending on configuration -
Max. process pressure (static)
depending on the configuration
-
Operating temperature range
PT100 TF StrongSens:
-50 °C ...500 °C
(-58 °F ...932 °F)
PT100 QuickSensTF:
-50 °C …200 °C
(-58 °F …392 °F)
PT100 WW:
-200 °C ...600 °C
(-328 °F ...1.112 °F)
PT100 TF:
-50 °C ...400 °C
(-58 °F ...752 °F)
Thermoelement:
Typ K up to 1.100 °C (2.012 °F)
Typ J up to 800 °C (1.472 °F)
Typ N up to 1.100 °C (2.012 °F) -
Max. immersion length on request
up to 4.500,0 mm (177'')
-
Selectare rapidă
Configurare individuală
-
Avantaje
-
User-friendly and reliable from product selection to maintenance
-
iTHERM inserts: globally unique, automated production. Full traceability and consistently high product quality for reliable measured values
iTHERM QuickSens: fastest response times 1.5 s...
-
-
Domeniu de aplicare
Universal range of application
Measuring range: –200 to +1100 °C (–328 to +2012 °F)
Pressure range up to 75 bar (1088 psi)
Degree of protection: up to IP 68
Vibration-resistant sensor elements up to 60g
Documente / Manuale / Software
-
iTHERM ModuLine TM111
Easy-to-use metric version with outstanding RTD or TC sensor technology
Technical Information (TI) -
Modular thermometers
Operating Instructions
Universal modular thermometers with RTD or TC insert for industrial
applicationsOperating Instruction (BA) -
iTHERM TM111, iTHERM TM131
ATEX: II 1/2G Ex ia IIC, II 1/2D Ex ia IIIC
IECEx: Ex ia IIC Ga/Gb, Ex ia IIIC Da/Db
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
TM111, TM131: cCSAus XP DIP NI
TM111, TM131: cCSAus XP DIP NI
Ex Safety Instructions (XA) -
iTHERM TM111, iTHERM TM131
ATEX: II 1/2G Ex db IIC, II 2G Ex db IIC, II 1/2D Ex ta/tb IIIC, II 2D
Ex tb IIIC
IECEx: Ex db IIC Ga/Gb, Ex db IIC Gb, Ex ta/tb IIIC Da/Db, Ex tb IIIC Db
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
iTHERM TM111, TM131
Ex d IIC T1...T6 Gb、Ex tD A20/A21 IP66/68 T
Ex Safety Instructions (XA) -
RTD/TC thermometers
ATEX II 3G, II 3D
Safety Instructions
Safety instructions for electrical apparatus certified for use in
explosion-hazardous areas.Ex Safety Instructions (XA) -
iTHERM TM111, TM131 Control drawing CSA IS, NI, DIP
Thermometer
Installation Notes for hazardous locations
Intrinsically safe, Nonincendive, Dust ignition proofEx Safety Instructions (XA) -
TRxx, TCxx, TS211, iTHERM TS111, TM211, TPx100, TSx310, TM1x1, TM411,
TM412
Thermometers and inserts
Ex nA IIC T6...T1 GcEx Safety Instructions (XA) -
TM111, TM131, TS111, TS211
Thermometers and inserts
Ex ia IIC T6 Ga/GbEx Safety Instructions (XA) -
Process RTD General purpose
Product Code: TM111-
Declaration Number: HE_01245_01.20
Manufacturer Specification: RoHSManufacturer DeclarationChineză -
Process TC Heavy duty, Process TC General purpose, Process TC direct in contact, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Direct contact, ACCESSORIES: T_INSERTS, ACCESSORIES: TC INSERT, ACCESSORIES: RTD INSERT
Product Code: TR11-, TR12-, TR13-, TR15-, TR24-, TR25-, TR45-, TR47-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TS111-, TSC310-, TST310-, TR10-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TEC420-, TM111-, TM131-, TM411-, TM412-, TPC100-, TPR100-
Declaration Number: EC_00169_02.16EU DeclarationGermană , Engleză , fr -
Process RTD General purpose
Product Code: TM111-, TM131-
Declaration Number: EC_00740_01.19EU DeclarationGermană , Engleză , fr -
Process RTD General purpose
Product Code: TM111-, TM131-
Declaration Number: EC_00735_01.19EU DeclarationGermană , Engleză , fr -
Process TC Heavy duty, Process TC General purpose, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Direct contact, Low cost RTD General purpose
Product Code: TM412-, TR10-, TR11-, TR12-, TR13-, TR15-, TR24-, TR25-, TR44-, TR45-, TR46-, TR47-, TR48-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TST40N-, TST41N-, TST434-, TM411-, TAF11-, TAF12D-, TAF12S-, TAF12T-, TAF16-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TEC420-, TM101-, TM111-, TM121-, TM131-, TM401-, TM402-
Declaration Number: EC_00136_02.16EU DeclarationGermană , Engleză -
ACCESSORIES: T_INSERTS, Process RTD General purpose
Product Code: TM111-, TM131-, TS111-, TS211-
Region/Country: Europe (ATEX)
Approval Agency: Bureau Veritas
Category: II 1/2 D, II 1/2 G, II 1 G
Protection: Ex ia IIC T6...T1 Ga, Ex ia IIC T6...T1 Ga/Gb, Ex ia IIIC Txxx°C Da/DbExplosion ProtectionGermană , Engleză -
ACCESSORIES: T_INSERTS, Process RTD General purpose
Product Code: TM111-, TM131-, TS111-, TS211-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex ia IIC T6...T1 Ga/GbExplosion ProtectionChineză -
Process RTD General purpose, Process RTD Hygienic
Product Code: TM111-, TM131-, TM411-, TM412-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D, I/1/A,B,C,D T6...T4, II,III/1/E,F,G, I/zone 1, I/zone 0
Protection: Ex ia IIC T6...T4 Ga, AEx ia IIC T6...T4 Ga, AEx/Ex [AEx/Ex ia] IIC T6...T4 GbExplosion ProtectionEngleză -
ACCESSORIES: T_INSERTS, Process RTD General purpose
Product Code: TM111-, TM131-, TS111-, TS211-
Region/Country: International (IECEx)
Approval Agency: Bureau Veritas
Protection: Ex ia IIC T6...T1 Ga, Ex ia IIC T6...T1 Ga/Gb, Ex ia IIIC Txxx°C Da/DbExplosion ProtectionEngleză -
ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, Process RTD Explosion proof, Process RTD General purpose, Process TC Explosion proof
Product Code: T13-, T14-, T15-, T53-, T54-, T55-, TM111-, TM131-, TU211-, TU221-
Region/Country: USA, Canada
Approval Agency: CSA
Category: II,III/1/E,F,G/TXXX°C, I/1/1/T6...T1, I/1/A,B,C,D/T6...T1, I/2/A,B,C,D/T6...T1
Protection: XP, NI, DIPExplosion ProtectionEngleză -
Process RTD General purpose
Product Code: TM111-, TM131-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 2 D, II 2 G, II 1/2 D, II 1/2 G
Protection: Ex tb IIIC Txxx°C Db, Ex ta/tb IIIC Txxx°C Da/Db, Ex db IIC T6...T1 Ga/Gb, Ex db IIC T6...T1 GbExplosion ProtectionEngleză -
Process RTD General purpose
Product Code: TM111-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex db IIC T6...T1 Ga/GbExplosion Protection -
Process RTD General purpose
Product Code: TM111-, TM131-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex tb IIIC Txxx°C Db, Ex ta/tb IIC Txxx°C Da/Db, Ex db IIC T6...T1 Ga/Gb, Ex db IIC T6...T1 GbExplosion ProtectionEngleză -
ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, ACCESSORIES: T_INSERTS, Process RTD Direct contact, Process RTD General purpose, Process RTD Heavy duty, Process RTD Hygienic, Process TC Direct contact, Process TC direct in contact
Product Code: TR11-, TR12-, TR13-, TR15-, TR24-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TS111-, TS211-, TSC310-, TST310-, TR10-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TM111-, TM131-, TM411-, TPC100-, TPR100-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex nA IIC T6...T1 GcExplosion ProtectionEngleză -
Process RTD General purpose
Product Code: TM111-, TM131-
Region/Country: China
Approval Agency: NEPSI
Protection: Ex d IIC T6...T1 Ga/Gb, Ex tD A20/A21 IP6XExplosion ProtectionChineză -
Process RTD General purpose
Product Code: TM111-
Region/Country: South Korea
Approval Agency: KTL
Protection: Ex tb IIIC Txxx°C DbExplosion Protection -
Process RTD Explosion proof, Process RTD General purpose, Process RTD Hygienic, Process TC Explosion proof
Product Code: T13-, T14-, T15-, T53-, T54-, T55-, TM111-, TM131-, TM411-, TM412-
Region/Country: USA, Canada
Approval Agency: CSAOrdinary Location Product SafetyEngleză -
Process RTD General purpose, Process RTD Hygienic
Product Code: TM111-, TM131-, TM411-, TM412-
Region/Country: Canada, USA
Approval Agency: CSAOrdinary Location Product SafetyEngleză
Accesorii / Piese de schimb
-
-
Order code 71182607
Spare parts kit sealing QuickNeck
10x O-ring 20x2.5 5x O-ring 25x3
-
Order code 71367427
-
Order code 71182599
Spare parts kit 5x O-Ring 78x3 VMQ 75°
-
Order code 71182602
Spare parts kit sealing TA30A/TA30D
5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75
-
Order code 71182606
Spare parts kit sealing TA30R
5x O-ring 57x2.5 5x O-ring 64.3x1.8 blau
-
Order code 71367414
-
Order code 71367425
-
Order code 71369768
O-Ring 71X3 silicone 70° Shore A
-
Order code 71438347
-
Order code TK40-
Compression Fitting TK40
Weld-in compression fitting with hygienic design. For applications in the food/ beverages and pharmaceutical industries.
-
Order code XPT0001-
-
Order code 71044061
Fixing kit cpl.TMT8x/7x (european)
2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector
-
Order code 71090687
Fieldbus connector PA M20;M12; L150
-
Order code XPT0004-
-
Order code TA20AB-
Terminal Head TA20AB
Terminal head for temperature assemblies, simple execution, lid fixed by screws. Inner geometry acc. to DIN EN 50446.
-
Order code TA30A-
Terminal Head TA30A
Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).
-
Order code TA30D-
Terminal Head TA30D
Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).
-
Order code TA30EB-
Terminal Head TA30EB
Retainer for terminal block or head transmitter + optional display. Cover: low, threaded, optional window. Material: Aluminium. Coating: Polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...+150oC (housing). Protection: IP66/68, NEMA 4X (housing).
-
Order code TA30H-
Terminal Head TA30H
Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50 150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).
-
Order code TA30P-
Terminal Head TA30P
Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing).
-
Order code TA30R-
Terminal Head TA30R
Retainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temp.: -50...85/130 oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact desing and low weight.
-
Order code TS111-
Insert iTHERM TS111
Replaceable. Metric version according DIN43735.
-
Order code READWIN-
Readwin 2000 Operation + Read. software
-
Order code TXU10-
Configuration Kit TXU10
for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.
-
Order code TMT180-
iTEMP TMT180, Head Transmitter Pt100
Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Order code TMT71-
iTEMP TMT71, Transmitter 4-20mA
2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
-
Order code TMT82-
iTEMP TMT82, Transmitter HART
2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.
-
Order code TMT84-
iTEMP TMT84, Transmitter PA
Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
Order code TMT85-
iTEMP TMT85, Transmitter FF
Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
Order code DIENST-
Service
-
Order code TMT72-
iTEMP TMT72, Transmitter HART
2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
-
-
Predecesor