Specificaţii pe scurt
-
Process temperature
Any
-
Process pressure / max. overpressure limit
Any
-
Max. measurement distance
Unlimited measuring range,
Cascade -
Accuracy
+/-1%
-
Main wetted parts
Non-contact
Domeniu de aplicare
The Gammapilot FMG50 compact transmitter is designed for non-contact point level detection, continuous level, interface and density measurement in liquids, solids, suspensions or sludges. As the first true 2-wire loop powered compact transmitter it minimizes engineering and installation efforts.
For all kinds of process vessels, like reactors, autoclaves, separators, acid tanks, cyclones
For liquids, solids, suspensions or sludges etc.
Extreme measuring conditions, for example corrosion, abrasion, viscosity, toxicity
Process temperature: No limitation (non-invasive)
Process pressure: No limitation (non-invasive)
Housing material: 316L, aluminum
International explosion protection certificates, SIL, overfill prevention WHG
Avantaje
First real 2-wire loop-powered compact transmitter minimizes engineering and installation efforts
Reduced installation and engineering costs thanks to the first 2-wire loop powered compact transmitter
Increased plant safety, efficiency and availability even under extreme process and ambient conditions
Designed according to IEC 61508 with SIL2/3 approval for all measuring tasks
Reduced verification effort and minimized plant shut-downs due to state-of-art Heartbeat Technology
-
Usage in up to +80°C (+176°F) ambient temperature without additional cooling thanks to innovative sensor technology
Bluetooth® wireless technology for remote operation out of the radiation beam
Clipuri video
-
-
The animation shows the radiometric measuring principle
Colecție Xpert
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
| Colecții FLEX | Excelenţă tehnică | Simplitate |
|---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
Measuring principle
Radiometric
-
Characteristic / Application
Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique -
Interface measurement
Interfaces liquid / liquid also with emulsion layers
Interfaces liquid / solid -
Specialities
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning, operation and maintenance with the SmartBlue App -
Supply / Communication
2-wire loop powered
-
Accuracy
+/-1%
-
Ambient temperature
-40 °C...+80 °C,
(-40 °F...+176 °F) -
Process temperature
Any
-
Process pressure / max. overpressure limit
Any
-
Main wetted parts
Non-contact
-
Process connection
Non-contact
-
Sensor length
PVT scintillator
400 mm...3000 mm,
>3000 mm cascade mode -
Max. measurement distance
Unlimited measuring range,
Cascade -
Communication
4...20 mA HART
-
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
-
Safety approvals
Overfill protection WHG
SIL 2/3 -
Design approvals
EN 10204-3.1
-
Options
Display
-
Components
Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
-
Measuring principle
Radiometric
-
Characteristic / Application
Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique -
Specialities
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning, operation and maintenance with the SmartBlue App -
Supply / Communication
2-wire loop powered
-
Accuracy
+/-1%
-
Ambient temperature
-40 °C...+80 °C,
(-40 °F...+176 °F) -
Process temperature
Any
-
Process pressure / max. overpressure limit
Any
-
Main wetted parts
Non-contact
-
Process connection
Non-contact
-
Sensor length
PVT scintillator
400 mm...3000 mm,
>3000 mm cascade mode -
Max. measurement distance
Unlimited measuring range,
Cascade -
Communication
4...20 mA HART
-
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
-
Safety approvals
Overfill protection WHG
SIL 2/3 -
Design approvals
EN 10204-3.1
-
Options
Display
-
Components
Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
-
Measuring principle
Radiometric Limit
-
Characteristic / Application
Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique -
Specialities
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning, operation and maintenance with the SmartBlue App -
Supply / Communication
2-wire loop powered
-
Ambient temperature
-40 °C...+80 °C,
(-40 °F...+176 °F) -
Process temperature
Any
-
Process pressure / max. overpressure limit
Any
-
Main wetted parts
Non-contact
-
Process connection
Non-contact
-
Sensor length
PVT scintillator:
200 mm...400 mm,
NAI scintillator:
50 x 50 mm,
50 x 100 mm -
Communication
4...20 mA HART
-
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
-
Safety approvals
Overfill protection WHG
SIL 2/3 -
Design approvals
EN 10204-3.1
-
Options
Display
-
Components
Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
-
Measuring principle
Radiometric Limit
-
Characteristic / Application
Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique -
Specialities
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning, operation and maintenance with the SmartBlue App -
Supply / Communication
2-wire loop powered
-
Ambient temperature
-40 °C...+80 °C,
(-40 °F...+176 °F) -
Process temperature
Any
-
Process pressure / max. overpressure limit
Any
-
Main wetted parts
Non-contact
-
Process connection
Non-contact
-
Sensor length
PVT scintillator:
200 mm...400 mm,
NAI scintillator:
50 x 50 mm,
50 x 100 mm -
Communication
4...20 mA HART
-
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
-
Safety approvals
Overfill protection WHG
SIL 2/3 -
Design approvals
EN 10204-3.1
-
Options
Display
-
Components
Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
-
Measuring principle
Radiometric Density
-
Characteristic / Application
Compact transmitter for extreme process conditions (temperature, pressure);
Non-contact measuring technique -
Supply / Communication
2-wire loop powered
-
Ambient temperature
-40 °C...+80 °C,
(-40 °F...+176 °F) -
Process temperature
Any
-
Process pressure
Any
-
Wetted parts
Non-contact
-
Sensor length
PVT scintillator:
200 mm...400 mm,
NAI scintillator:
50 x 50 mm,
50 x 100 mm -
Output
4...20 mA HART
-
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI, INMETRO, EAC Ex, JPN Ex, KC Ex
-
Options
Display
-
Specialities
Heartbeat Technology,
SIL 2/3 according to IEC 61508,
Bluetooth® commissioning, operation and maintenance with the SmartBlue App -
Components
Isotope: FSG60, FSG61,
Source container: FQG60, FQG61, FQG62, FQG63, FQG66,
Mounting accessories: FHG61
-
-
Informaţii tehnice (TI)
TI Gammapilot FMG50
-
Informaţii tehnice (TI)
Versiune în limba engleză - 12/2025New version available in EnglishRadiometric measuring technology
EN RO 19/12/202503/06/202417/02/202230/03/202016/08/2019Limbă:
Engleză
Versiune:
19/12/2025
Dimensiune fişier:
4.4 MB
Nume fişier:
TI01462FEN_0525-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Gammapilot FMG50
-
Instrucţiuni de operare (BA)
Versiune în limba engleză - 10/2025New version available in EnglishRadiometric measuring technology
EN RO 30/10/202503/06/202430/08/202208/03/202216/08/2021Limbă:
Engleză
Versiune:
30/10/2025
Dimensiune fişier:
7.4 MB
Nume fişier:
BA01966FEN_0725-00.pdf
-
-
-
Parametru dispozitiv (GP)
Gammapilot FMG50
-
Parametru dispozitiv (GP)
Versiune în limba engleză - 08/2019New version available in EnglishRadiometric measurement
EN RO 22/08/2019Limbă:
Engleză
Versiune:
22/08/2019
Dimensiune fişier:
362.1 KB
Nume fişier:
GP01141FEN_0119.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Gammapilot FMG50 HART
-
Instrucţiuni scurte (KA)
Versiune în limba română - 06/2024New version available in EnglishTehnologie de măsurare radiometrică
EN RO 19/12/202503/06/202410/07/202301/12/202016/08/2019Limbă:
Română
Versiune:
03/06/2024
Dimensiune fişier:
1.1 MB
Nume fişier:
KA01427FRO_0424-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
NaI scintillator
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 09/2020New version available in EnglishGammapilot FMG50
EN RO 11/09/202016/08/2019Limbă:
Engleză
Versiune:
11/09/2020
Dimensiune fişier:
268.1 KB
Nume fişier:
EA01274FEN_0220.pdf
-
-
-
Instrucţiuni de instalare (EA)
Mounting clamp 80 mm, 95 mm Installation Instructions
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 08/2019New version available in EnglishGammapilot FMG50
EN RO 16/08/2019Limbă:
Engleză
Versiune:
16/08/2019
Dimensiune fişier:
158 KB
Nume fişier:
EA01271FEN_0119.pdf
-
-
-
Instrucţiuni de instalare (EA)
PVT scintillator
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 09/2020New version available in EnglishGammapilot FMG50
EN RO 11/09/202016/08/2019Limbă:
Engleză
Versiune:
11/09/2020
Dimensiune fişier:
330.3 KB
Nume fişier:
EA01275FEN_0220.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA HAN7D plug, 90 deg, housing side HAN7D socket, cable side
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 09/2025New version available in EnglishGammapilot, Micropilot,
Cerabar, DeltabarEN RO 12/09/202530/11/202327/05/202009/08/2019Limbă:
Engleză
Versiune:
12/09/2025
Dimensiune fişier:
796.2 KB
Nume fişier:
EA01268FEN_0425-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Housing
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 09/2025New version available in EnglishGammapilot, Cerabar, Deltabar
EN RO 19/09/202510/03/202311/09/2020Limbă:
Engleză
Versiune:
19/09/2025
Dimensiune fişier:
2 MB
Nume fişier:
EA01330FEN_0325-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Ground terminal
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 03/2025New version available in EnglishGammapilot, Micropilot, Liquiphant
Cerabar, Deltabar, Prowirl LEN RO 28/03/202520/02/202325/05/2020Limbă:
Engleză
Versiune:
28/03/2025
Dimensiune fişier:
465.5 KB
Nume fişier:
EA01306FEN_0325-00.pdf
-
Alegeţi dintre opţiunile noastre sugerate
-
-- selected coding-- selected label99.999,00<%label%>
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Desene CAD Desene CAD
- Desene CAD
-
Preţuri pe bucată
-
<%range%><%price%>
-
- Accesorii opţionale
Configurare individuală
Frecvent cumpărate împreună
Accesorii
Produse asociate