Specificaţii pe scurt
-
Measuring range
0 to 500 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method + dilution module (1:4) -
Process temperature
4 to 40 °C (39 to 104 °F)
-
Process pressure
Atmospheric
Domeniu de aplicare
Liquiline System CA80COD offers constant online measurement of the chemical oxygen demand (COD). It supports you in monitoring the cleaning capacity of wastewater treatment plants and enables load-based billing for industrial dischargers. Automatic calibration and cleaning save operating costs while advanced diagnostics with remote access help to provide process documentation to authorities. The COD analyzer's software-controlled safety functions ensure the highest level of occupational safety.
The Liquiline System COD analyzer monitors:
Inlet and outlet of wastewater treatment plants for documentation purposes and calculation of the cleaning capacity
Discharges of industrial wastewater treatment plants to determine discharge fees and to support the polluter-pays-principle
Process water
Avantaje
Established COD dichromate method directly comparable to laboratory results.
Meeting industry needs: The analyzer is perfectly suited for environmental monitoring, industrial and municipal wastewater.
Fast and easy process integration: Direct installation of self-priming version or y-strainer for bypass applications.
Safety on the highest level: Software-controlled safety cover for the reactor and all heated parts.
-
Combination of reliable sample delivery and high-precision dosing: Peristaltic pumps are able to cope with particles in the sample. Light barriers enable precise, reproducible dosing.
Easy upgrade of functionality to a complete measuring station - simply by adding modules and connecting Memosens sensors.
Drive connectivity: Liquiline Edge Module CYY7 transfers process data to Netilion, independently of the fieldbus. This allows remote overview and the use of IIoT services. It’s available in new products or as upgrade to installed Liquiline platforms.
Clipuri video
-
The chemical oxygen demand (COD) of a liquid can be determined using chemical and thermal digestion and the colorimetric measuring principle. This video shows how this measuring principle works.
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
| Colecții FLEX | Excelenţă tehnică | Simplitate |
|---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
Measuring principle
Colorimetric
-
Characteristic
Analyzer for chemical oxygen demand (COD)
-
Size
Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in -
Design
Open design, cabinet and stand housing
High-Performance plastic ASA-PC, additional stand coated steel -
Process temperature
4 to 40 °C (39 to 104 °F)
-
Ambient temperature
5 to 40 °C (41 to 104 °F)
Outdoor version: - 20 to 40 °C (-4 to 104 °F) -
Process pressure
Atmospheric
-
Sample flow rate
min. 30 ml/min
-
Consistency of the sample
Aqueous homogeneous sample
-
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
Self-priming analyzer with optical dosing unit l
Dilution module (optional)
Digital communication for remote access -
Application
Environmental monitoring, limit value monitoring of industrial and municipal waste water
-
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10%
50 ± 1 oder 60 ± 1,2 Hz -
Output / communication
2x 0/4 to 20 mA
Modbus RS485/TCP (optional)
Webserver (optional)
EtherNet/IP
PROFIBUS DP
Alarmrelay -
Input
1 measuring channel
1 to 4 digital sensor inputs for sensors with Memosens protocol (optional) -
Measuring range
0 to 500 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method
0 to 5000 mg/l O2 COD chromate method + dilution module (1:4) -
Consumables
Reagents and standard solutions CY80COD are necessary for the operation
-
-
Instrucţiuni de operare (BA)
Memosens
-
Instrucţiuni de operare (BA)
Versiune în limba rusă - 05/2022New version available in EnglishВходы датчиков с технологией Memosens
EN RO 30/05/202228/02/201930/05/2018Limbă:
Rusă
Versiune:
30/05/2022
Dimensiune fişier:
3.5 MB
Nume fişier:
BA01245CRU_0822-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Kits for Analyzer CA80: Engineering parts
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 06/2025New version available in EnglishKits for Analyzer CA80: Engineering parts
EN RO 30/06/2025Limbă:
Engleză
Versiune:
30/06/2025
Dimensiune fişier:
2.1 MB
Nume fişier:
71223028 Anleitung Kits CA8x Verfahrenstechnik 2022-08.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Liquiline System analyzer CA80COD/TP
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 10/2025New version available in EnglishWear parts
EN RO 31/10/2025Limbă:
Engleză
Versiune:
31/10/2025
Dimensiune fişier:
3.1 MB
Nume fişier:
EA01718CEN_0125-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Liquiline System analyzer CA80COD/TP
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 12/2025New version available in EnglishCarrier plate components
EN RO 04/12/202516/07/2025Limbă:
Engleză
Versiune:
04/12/2025
Dimensiune fişier:
5.4 MB
Nume fişier:
EA01677CEN_0225-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Liquiline System CA8x analyzer
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 08/2025New version available in EnglishConversion of electronics modules
EN RO 26/08/202526/06/2025Limbă:
Engleză
Versiune:
26/08/2025
Dimensiune fişier:
2.4 MB
Nume fişier:
EA01617CEN_0225-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Liquiline System CA8x analyzer
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 09/2025New version available in EnglishProcess engineering
EN RO 17/09/202521/03/2025Limbă:
Engleză
Versiune:
17/09/2025
Dimensiune fişier:
3.8 MB
Nume fişier:
EA01591CEN_0225-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Kits for Analyzer CA8x: Housing parts
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 03/2025New version available in EnglishInstallation instruction: Kits for Analyzer CA8x: Housing parts
EN RO 03/03/2025Limbă:
Engleză
Versiune:
03/03/2025
Dimensiune fişier:
957.4 KB
Nume fişier:
71223031 Anleitung Kits CA8x Gehaeuseteile 2022-06.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA CA8x/CAT8xx
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 06/2025New version available in EnglishHose connector
EN RO 23/06/2025Limbă:
Engleză
Versiune:
23/06/2025
Dimensiune fişier:
2 MB
Nume fişier:
EA01522CEN_0225-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Kit manual for sample preparation systems CAT8xx Filter
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 01/2026New version available in EnglishKit manual for sample preparation systems CAT8xx Filter - two-sided
EN RO 16/01/2026Limbă:
Engleză
Versiune:
16/01/2026
Dimensiune fişier:
2.1 MB
Nume fişier:
71223012 Anleitung Kits CAT8xx Filter 2020-06.pdf
-
-
-
Instrucţiuni de instalare (EA)
Liquiline modules collection instructions
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 06/2025New version available in EnglishLiquiline modules collection instructions
EN RO 30/06/2025Limbă:
Engleză
Versiune:
30/06/2025
Dimensiune fişier:
1 MB
Nume fişier:
71104852_cm44xsammel.pdf
-
Alegeţi dintre opţiunile noastre sugerate
-
-- selected coding-- selected label99.999,00<%label%>
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Desene CAD Desene CAD
- Desene CAD
-
Preţuri pe bucată
-
<%range%><%price%>
-
- Accesorii opţionale
Configurare individuală
Frecvent cumpărate împreună
Accesorii
Produse asociate