Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Starter: 785 nm
Base Model: 532 nm, 785 nm, 1000 nm
Hybrid: 785 nm
Starter 785 nm: 300-3300 cm-1
Base model 532 nm: 150-4350 cm-1
Base model 785 nm: 150-3425 cm-1
Base model 1000 nm: 200-2400 cm-1
Hybrid 785 nm: 175-1890 cm-1
Adeptly harness the power of Raman spectroscopy with the Raman Rxn2 analyzer. Designed for use in analytical laboratories with model transfer capabilities, the Raman Rxn2 is heavily relied on for routine sample identification, support of R&D projects, early process development, and scale-up settings for in situ analysis. Available as a benchtop or on a mobile wheeled cart, the Raman Rxn2 offers location convenience and portability for process development laboratories.
Chemical: polymerization, extrusion monitoring, polymer blending, catalysis investigation
Pharmaceutical: reaction chemistry, yield crystallization, polymorph, blending, drying, granulations
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: cultured meat, fermentation, oil or fat quality
Reliable real-time, in situ measurements
Intuitive, embedded control software via touchscreen or remote interface
Convenience of a single base unit supporting up to four probes
Sequential operation for fast analysis per channel and programmable channel interrogation
Converts acquired Raman spectra into process knowledge using built-in multivariate predictors
Suitable for outputs into hazardous area/classified environments
Proven model transferability to process development and manufacturing scales
Produse superioare
Excelenţă tehnică
Simplitate
Produse de specialitate
Excelenţă tehnică
Simplitate
Variabil
| Colecții FLEX | Excelenţă tehnică | Simplitate |
|---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
System information and specifications for the Raman data library 2.1
| EN | RO | ||
|
08/09/2025
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
08/09/2025 |
|
Dimensiune fişier: |
191.3 KB |
|
Nume fişier: |
TI01869CEN_0125.pdf |
Commissioning, operation, and maintenance details
for Raman RunTime v6.6 software
| EN | RO | ||
|
27/03/2025
|
|
|
|
|
16/11/2023
|
|
|
|
|
31/12/2020
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
27/03/2025 |
|
Dimensiune fişier: |
6.8 MB |
|
Nume fişier: |
BA02180CEN_0525.pdf |
Instructions for administration of Raman data library 2.1 software
| EN | RO | ||
|
08/09/2025
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
08/09/2025 |
|
Dimensiune fişier: |
1.2 MB |
|
Nume fişier: |
BA02564CEN_0125.pdf |
Instructions for use of Raman data library 2.1
| EN | RO | ||
|
08/09/2025
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
08/09/2025 |
|
Dimensiune fişier: |
4.5 MB |
|
Nume fişier: |
BA02563CEN_0125.pdf |
Quick start guide for the Raman Rxn5 analyzer -
powered by Kaiser Raman technology
| EN | RO | ||
|
13/03/2025
|
|
|
|
|
16/01/2025
|
|
|
|
|
21/11/2023
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
13/03/2025 |
|
Dimensiune fişier: |
2.1 MB |
|
Nume fişier: |
KA01554CEN_0425.pdf |
Quick start guide for the Raman Rxn2 analyzer -
powered by Kaiser Raman technology
|
Limbă: |
Engleză |
|
Versiune: |
21/11/2023 |
|
Dimensiune fişier: |
2.5 MB |
|
Nume fişier: |
KA01544CEN_0323.pdf |
Hazardous area certifications and installation instructions
for the Raman Rxn2 analyzer - powered by Kaiser Raman technology
| EN | RO | ||
|
07/12/2023
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
07/12/2023 |
|
Dimensiune fişier: |
1.1 MB |
|
Nume fişier: |
XA02700CEN_0323.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Limbă: |
Engleză |
|
Versiune: |
26/06/2025 |
|
Dimensiune fişier: |
363.4 KB |
|
Nume fişier: |
PU01611CEN_0125.pdf |
Graphic illustrating the core elements of Biopharma 4.0 including
product lifecycle stages, role of PAT/QbD, and 12 key advanced
technologies for scientists and process engineers in the Life
Sciences, applicable to Raman spectroscopy systems (Raman
Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and
sleeve, flow cell and flow bench, Raman optic system for single
use, and Raman calibration & verification kits).
|
Limbă: |
Engleză |
|
Versiune: |
22/05/2025 |
|
Dimensiune fişier: |
481.6 KB |
|
Nume fişier: |
PU01614CEN_0125.pdf |
An overview of the Raman flow assembly (flow bench and flow cell)
used with the Rxn-10 probe in conjunction with a Raman Rxn2
analyzer and a Raman flow assembly calibration and verification kit
for downstream bioprocessing (powered by Kaiser Raman technology).
|
Limbă: |
Engleză |
|
Versiune: |
31/05/2023 |
|
Dimensiune fişier: |
837 KB |
|
Nume fişier: |
PU01517CEN_0123.pdf |