Liquiphant FTL80 - Vibronic

Vibronic
Point level detection
Liquiphant FTL80

Point level switch for liquids for FailSafe overfill protection

FTL80
Please Wait (spinning wheel)
Se încarcă preţul
Preţurile sunt temporar indisponibile
Price on request
Filtrare măsurători / aplicaţie
Activitate de măsurare / aplicaţie

Configurare pentru descărcarea desenelor CAD ale acestui produs

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Compact point level switch for MIN and MAX safety applications up to SIL3,
    Dual Sealing/ Second line of defense
    Modular housing concept

  • Specialities

    Outstanding features:
    - permanent LIVE signal monitors function safety
    - failsafe design and
    - high availability of the measuring values

  • Supply / Communication

    2-wire 4...20 mA

  • Ambient temperature

    -60°C...+70°C
    (-76°F...+160°F)

  • Process temperature

    -60°C...+280°C
    (-76°F...+540°F)

  • Process pressure / max. overpressure limit

    Vacuum...100 bar
    (1450 psi)

  • Min. density of medium

    Density from 0.4 g/cm3
    (0.4 SGU)

  • Main wetted parts

    316L,
    Alloy C

  • Process connection

    Flange:
    DN25...DN100
    ASME 1"...4"
    JIS 10K...20K
    Thread:
    G3/4, G1, R3/4,
    R1, MNPT3/4, MNPT1

  • Sensor length

    Compact

  • Communication

    2-wire 4...20 mA

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC

  • Safety approvals

    Overfill protection WHG
    Leakage
    SIL3

  • Design approvals

    EN 10204-3.1
    NACE MR0175, MR0103
    ASME B31.3
    AD2000

  • Marine approval

    GL/ ABS/ LR/ BV/ DNV

  • Options

    PWIS free
    Pressure tight feed through
    Weather protection

  • Components

    Nivotester FTL825, Transmitter