Configurare pentru descărcarea desenelor CAD ale acestui produs

  • Measuring principle

    Hydrostatic pressure

  • Characteristic

    Compact probe with metallic cell for hydrostatic level measurement
    in fresh water, ground water and potable water storage.

  • Supply voltage

    8...28 VDC

  • Reference Accuracy

    pn ≥ 400mbar: 0.35 %
    pn < 400mbar: 0.50 %

  • Long term stability

    0.1 % of URL/year

  • Process temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Ambient temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Measuring cell

    200 mbar...2 bar
    (3 psi...29 psi)

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Material process membrane

    Metal

  • Communication

    4...20 mA

  • Drinking water approvals

    NSF, KTW, ACS

  • Measuring principle

    Hydrostatic

  • Characteristic / Application

    Compact probe with metallic cell for hydrostatic level measurement
    in fresh water, ground water and potable water storage.

  • Supply / Communication

    8...28 VDC

  • Accuracy

    pn ≥ 400mbar: 0.35 %
    pn < 400mbar: 0.50 %

  • Long term stability

    0.1% of URL/year

  • Ambient temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Process temperature

    -10°C...+70°C
    (+14°F...+158°F)

  • Process pressure / max. overpressure limit

    10 bar (145 psi)

  • Pressure measuring range

    200 mbar...2 bar
    (3 psi...29 psi)

  • Main wetted parts

    316L

  • Process connection

    Suspension clamp
    Cable mounting screws

  • Max. measurement distance

    20 m H2O
    (66 ft H2O)

  • Communication

    4...20 mA

  • Drinking water approvals

    NSF, KTW, ACS