Proline Promag P 300
Electromagnetic flowmeter
High-temperature flowmeter for process applications with a compact, easily accessible transmitter
Promag P is dedicated to chemical and process applications with corrosive liquids and highest medium temperatures. With its compact transmitter Promag P 300 offers a high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology ensures compliance and process safety at all times.
- F
- L
- E
- X
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
Specificaţii pe scurt
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s) -
Measuring range
4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner: PFA; PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium; Duplex 1.4462 (UNS S31803)
-
Selectare rapidă
Configurare individuală
-
Avantaje
Diverse applications – wide variety of wetted materials
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
Full access to process and diagnostic information – numerous, freely combinable I...
-
Domeniu de aplicare
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
Device properties
Nominal diameter: max...
Documente / Manuale / Software
-
Proline Promag P 300
Technical Information
Electromagnetic flowmeter
High-temperature flowmeter for process applications with a compact,
easily accessible transmitterTechnical Information (TI) -
Proline Promag P 300
PROFIBUS PA
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 300
PROFINET
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 300
FOUNDATION Fieldbus
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 300
EtherNet/IP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 300
HART
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 300
PROFIBUS DP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 300
Modbus RS485
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 300
HART
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 300
Modbus RS485
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 300
PROFINET
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 300
EtherNet/IP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 300
PROFIBUS PA
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 300
FOUNDATION Fieldbus
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 300
PROFIBUS DP
Description of Device Parameters
Electromagnetic flowmeter
Proline Promag 300
PROFIBUS DPDevice Parameter (GP) -
Proline 300
PROFIBUS PA
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)11/18Engleză -
Proline Promag P
Brief Operating Instructions
Proline Promag P
Electromagnetic sensorShort Instruction (KA)10/17Engleză -
Proline 300
FOUNDATION Fieldbus
Brief Operating Instructions
Transmitter with Coriolis sensor
Short Instruction (KA)08/18Engleză -
Proline 300
Modbus RS485
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16Engleză -
Proline 300
HART
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)08/16Engleză -
Proline Promag
Brief Operating Instructions
Proline Promag
Part 1 of 2
Electromagnetic sensorShort Instruction (KA)04/17Engleză -
Flowmeter
Proline 300
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19Engleză -
Flowmeter
Proline 300
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19Engleză -
Flowmeter
Proline 300
Brief Operating Instructions
Transmitter with
electromagnetic sensorShort Instruction (KA)02/19Engleză -
Flowmeter
Proline 300
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19Engleză -
Flowmeter
Proline 300
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19Engleză -
Flowmeter
Proline 300
Modbus RS485
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19Engleză -
Flowmeter
Proline 300
Brief Operating Instructions
Transmitter with electromagnetic sensor
Short Instruction (KA)02/19Engleză -
Conversion Kit for Promag, Promass 300 Compact Version to Promag,
Promass 500 Remote Version
Installation Instructions
Promag, Promass 300, 500
Installation Instructions (EA) -
Replacing cover, O-ring cover, Interface gasket
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Alteration to Display module, to Display module with WirelessHART or
Display module with WLAN
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing ISEM electronics module, ISEM extender, ribbon cable
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing the S-DAT
Installation Instructions
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the display module
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digital, DKX001–Installation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Alteration with display and operating module DKX001
Promag, Promass, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Installing ground disks
Promag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
Installation Instructions (EA) -
Replacing the transmitter
Installation Instructions
, , Promag 300
Installation Instructions (EA) -
Protective Cover connection compartment
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Activating application packages, switching the I/O function, upgrading
with additional I/O hardware
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the transmitter Promag, Promass 300
Installation Instruction
Promag 300, Promass 300Installation Instructions (EA) -
Replacing cover, O-ring, seal housing for transmitter wall mounting and
seal housing for the sensor side
Promag, Promass 500, 500-digital, Prosonic Flow, t-mass 500-digital
Installation Instructions (EA) -
Replacing the electronics
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Replacing RJ45-M12 Adapter
Proline 300, 500-digital
Installation Instructions (EA) -
Kit wireless antenna for extended range
Promag, Promass 300, 500, 500-digital, Prosonic Flow 300, 500-digital,
t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing the terminal connection
Promag, Promass 300, 500, 500-digital, Prosonic Flow, t-mass 300,
500-digitalInstallation Instructions (EA) -
Alteration with correspondent I/O hardware for HART, Modbus
Promag, Promass 300, 500, 500-digital
Installation Instructions (EA) -
Replacing cover for remote display module, O-ring for cover
Promag, Promass, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Weather Protection
Promag, Promass 300, 500, Prosonic Flow, t-mass 300
Installation Instructions (EA) -
Proline Promag 300
ATEX:
II3G
IECEx:
Zone 2Ex Safety Instructions (XA) -
Proline Promag 300
Class I Zone 2
Class I Division 2Ex Safety Instructions (XA) -
Proline Promag 300
ATEX:
II2G
II2D
IECEx:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 300
JPN:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 300
EAC:
1Ex d e ia [ia Ga] IIC T6…T1 Gb X,
Ex tb [ia Da] IIIC T Db X,
or
1Ex d e ia IIC T6…T1 Gb X,
Ex tb IIIC T Db XEx Safety Instructions (XA) -
Proline Promag 300
Cl. I, II, III Div.1 for XP
(Ex d Flameproofed version)Ex Safety Instructions (XA) -
Proline Promag 300
INMETRO:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 300
Class I, Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 300
INMETRO:
Zone 2Ex Safety Instructions (XA) -
Proline Promag 300
EAC:
2Ex nA nC ic IIC T5…T1 Gc XEx Safety Instructions (XA) -
Proline Promag 300
NEPSI:
Zone 1
Zone 21Ex Safety Instructions (XA) -
Proline Promag 300
NEPSI:
Zone 2Ex Safety Instructions (XA) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Remote display and operating module DKX001
Special Documentation
Remote display and operating module DKX001
Special Documentation (SD) -
Proline Promag 300
FOUNDATION Fieldbus
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 300
Modbus RS485
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag P 300, 500
FOUNDATION Fieldbus, PROFIBUS PA
Special Documentation
Proline Promag P 300, 500; FOUNDATION Fieldbus, PROFIBUS PA
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Proline Promag 300
PROFINET
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 300
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 300
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 300
Functional Safety Manual
Special Documentation (SD) -
Proline Promag 300
PROFINET
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 300
FOUNDATION Fieldbus
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Display modules A309/A310
Display with WLAN interface
Special Documentation (SD) -
Proline Promag 300
PROFIBUS PA
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 300
HART
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 300
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 300
Modbus RS485
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 300
PROFIBUS PA
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 300
EtherNet/IP
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 300
HART
OPC-UA Server application package
for IIoT and SCADA applications
Special Documentation
Special Documentation
OPC-UA Server
For IIoT and SCADA applicationsSpecial Documentation (SD) -
Proline Promag 300
PROFIBUS DP
Heartbeat Verification + Monitoring application package
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 300 500 Modbus RS485: 1.01.01Manufacturer Information (MI) -
Proline Promag 300 / 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300 / 500 PROFIBUS PA: 1.01.00Manufacturer Information (MI) -
Proline Promag 300 500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300 500 HART: 1.05.00Manufacturer Information (MI) -
Proline Promag 300 500
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 300 500 HART: 1.01.01Manufacturer Information (MI) -
Proline Promag 300/500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300/500 Modbus RS485: 1.05.00Manufacturer Information (MI) -
Proline Promag 300/500
Manufacturer information regarding firmware update (NE 53)
New Firmware version:
Promag 300/500 PROFINET: 1.01.00Manufacturer Information (MI) -
Industrial Ethernet für Proline Durchflussmessgeräte
Die Systemintegration der Zukunft
Innovations (IN)12/17Germană -
Industrial Ethernet for Proline flowmeters
The system integration of the future
Innovations (IN)12/17Engleză -
Proline 300/500
La technologie de mesure de débit orientée vers l’avenir
Innovations (IN)09/18fr -
Proline 300/500
La tecnologia di misura della portata orientata al futuro
Innovations (IN)05/16Italiană -
Proline 300/500
La tecnología de medición de caudal del futuro
Innovations (IN)05/16Spaniolă -
Proline 300/500
American version: The future-oriented flow measuring technology
Innovations (IN)05/16Engleză -
Proline 300/500
Technologie měření průtoku orientovaná na budoucnost
Innovations (IN)05/16Cehă -
Proline 300/500
Die zukunftsweisende Durchfluss-Messtechnik
Innovations (IN)03/18Germană -
Proline 300/500
The future-oriented flow measuring technology
Innovations (IN)03/18Engleză -
流量計 Proline 300/500
未来志向の流量測定技術
Innovations (IN)03/18Japoneză -
Promag P300
Magnetisch-induktives Durchflussmessgerät kompakte Bauform zur
bidirektionalen
Messung von Flüssigkeiten mit einer Mindestleitfähigkeit von ≥ 5 μS/cm.Tender Text06/20Germană -
GSD Single, GSD_PN_FL_Promag300500_0x843C_0x02, 10.09.2019 (Flow, Promag 300 500, 0x843C)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_EH_PA_FL_Promag300_500_0x156C_0x01_0x01, 08.08.2016 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_DP_FL_Promag_300500_0x1570_0x01_0x01, 04.06.2018 (Flow, Promag 300 500, 0x1570)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PA_FL_Promag300500_0x156C_0x02, 09.11.2018 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_PN_FL_Promag300500_0x843C_0x01_0x01, 16.11.2017 (Flow, Promag 300 500, 0x843C)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EIP_FL_Promag_300500_0x103C_0x01_0x01, 09.01.2020 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.3Language neutral -
EDD Single, PDM_PA_FL_Promag300_500_0x156C_0x01_0x01, 09.08.2016 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PDM Version: 6.1, 8.2.1, 9.0, 9.1Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, PDM_HART_FL_Promag300_500_0x003C_0x01_0x01, 09.08.2016 (Flow, Promag 300 500, 0x113C)
HART,
PDM Version: 6.1, 8.2.1, 9.0Electronic Data Description (EDD)1.00.01Language neutral -
EDD Single, AMS12_HART_FL_Promag300_500_0x113C_0x06_0x01, 25.09.2020 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5, 14.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag300_500_0x113C_0x06_0x01, 25.09.2020 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promag300_500_0x843C_0x02_0x01, 20.09.2019 (Flow, Promag 300 500, 0x843C)
PROFINET,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag300_500_0x113C_0x02_0x01, 27.11.2017 (Flow, Promag 300 500, 0x113C)
HART,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag300_500_0x113C_0x01_0x01, 20.08.2019 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag300_500_0x113C_0x01_0x01, 20.08.2019 (Flow, Promag 300 500, 0x113C)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag300_500_0x113C_0x02_0x01, 28.11.2017 (Flow, Promag 300 500, 0x113C)
HART,
Experion Version: R432.1
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag300_500_0x003C_0x01_0x01, 09.08.2016 (Flow, Promag 300 500, 0x113C)
HART,
Field Device Manager Version: R450.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN-CDIE_FL_Promag300_500_0x843C_0x01_0x01, 27.11.2017 (Flow, Promag 300 500, 0x843C)
PROFINET,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FCx75_HART_FL_Promag300500_0x113B_0x01_0x01, 22.02.2017 (Flow, Promag 300 500, 0x113C)
HART, Package: Package, Variant: Variant
FC475 Version: 2.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 10.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS13_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 13.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag300_500_0x113C_0x06_0x01, 10.09.2019 (Flow, Promag 300 500, 0x113C)
HART,
Experion Version: R500
Field Device Manager Version: R500Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
AMS Version: 11.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag300_500_0x113C_0x06_0x01, 20.09.2019 (Flow, Promag 300 500, 0x113C)
HART,
PDM Version: 8.2.1, 9.1.0.4Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PN_FL_Promag300_500_0x843C_0x01_0x01, 27.11.2017 (Flow, Promag 300 500, 0x843C)
PROFINET,
PDM Version: 8.2.1, 9.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS10_5_HART_FL_Promag300_500_0x113C_0x02_0x01, 22.11.2018 (Flow, Promag 300 500, 0x113
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EDD_FF_FL_Promag300500_0x103C_0x01_0x01, 29.09.2017 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_FL_Promag300500_0x156C_0x02_0x01, 18.01.2019 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
PDM Version: 8.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag300500_0x1570_0x01_0x01, 16.07.2018 (Flow, Promag 300 500, 0x1570)
PROFIBUS DP,
PDM Version: 8.2.1, 9.1.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_0_HART_FL_Promag300_500_0x113C_0x02_0x01, 22.11.2018 (Flow, Promag 300 500, 0x113
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promag_300_500_0x103C_FF_FW1_00_zz_Dev_Rev_01, 22.10.2020 (Flow, Promag 300 500, 0x103C)
FOUNDATION Fieldbus H1,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1
Plant Resource Manager Version: R3.20Device Type Manager (DTM)1.9.0.122Language neutral -
DTM Single, Promag_300_500_0x003C_FW_1_00_zz_Dev_Rev_1, 27.10.2020 (Flow, Promag 300 500, 0x113C)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 4.1 SP4
Plant Resource Manager Version: R3.12Device Type Manager (DTM)1.8.0.139Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.8.0.130Language neutral -
DTM Single, Promag_300_500_HART_FW_1_06_00_Dev_Rev_06, 27.10.2020 (Flow, Promag 300 500, 0x113C)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R500
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.285Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_05_zz_Dev_Rev_06, 04.10.2019 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.03.00
FieldCare Version: 2.13.00Device Type Manager (DTM)1.39.0.230Language neutral -
DTM Single, Promag_300_500_MR4_FW_1_05_zz_Dev_Rev_06, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.230Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_05_zz_Dev_Rev_06, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.230Language neutral -
DTM Single, Promag300500_PN-CDIE_FW_1_01_zz_Dev_Rev_02, 05.11.2020 (Flow, Promag 300 500, 0x843C)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.39.0.136Language neutral -
DTM Single, Promag_300_500_5x3x-5x5x_FW_1_01_zz_Dev_Rev_02, 21.10.2020 (Flow, Promag 300 500, 0x156
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0Device Type Manager (DTM)1.12.0.161Language neutral -
DTM Single, Promag_300_500_DP_FW_1_00_zz_Dev_Rev_01, 19.10.2020 (Flow, Promag 300 500, 0x1570)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0Device Type Manager (DTM)1.11.0.65Language neutral -
DTM Single, Promag_300_500_0x156C_FW_1_00_zz_Dev_Rev_1, 21.10.2020 (Flow, Promag 300 500, 0x156C)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.11.0.104Language neutral -
DTM Single, Promag300500_PN-CDIE_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promag 300 500, 0x843C)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.65Language neutral -
DTM Single, Promag_300_500_EIP-CDIE_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.59Language neutral -
DTM Single, Promag_300_500_EIP_FW_1_00_zz_Dev_Rev_01, 05.11.2020 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
Unity Pro XL Version: 11.1Device Type Manager (DTM)1.10.0.59Language neutral -
DTM Single, Promag_300_500_HART_FW_1_01_zz_Dev_Rev_02, 27.10.2020 (Flow, Promag 300 500, 0x113C)
HART,
ArchestrA IDE Version: 4.0.04001
DeviceCare Version: 1.07.00
Field Device Manager Version: R450.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
PACTware Version: 5.0
Plant Resource Manager Version: R3.31Device Type Manager (DTM)1.10.0.223Language neutral -
DTM Single, Promag_300_500_MR4_FW_1_01_zz_Dev_Rev_02, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.207Language neutral -
DTM Single, Promag_300_500_MR4-CDIE_FW_1_01_zz_Dev_Rev_02, 06.11.2020 (Flow, Promag 300 500, 0x643C)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.10.0.207Language neutral -
AOP Single, RS_EIP_FL_Promag300500_0x103C_0x01_0x01_AOP, 28.08.2019 (Flow, Promag 300 500, 0x103C)
EtherNet/IP,
RA RSLogix 5000 Version: V20.04and later
RA Studio 5000 Version: V21 and laterAdd On Profile (AOP)1.10Language neutral -
Faceplate Single, PRM_HART_FL_Promag300_500_0x003C_0x01_0x01, 08.08.2016 (Flow, Promag 300 500, 0x1
HART,
Plant Resource Manager Version: R3.20Faceplate1.00.01Language neutral -
Faceplate Single, PRM_HART_FL_Promag300_500_0x113C_0x06_0x01, 10.09.2019 (Flow, Promag 300 500, 0x1
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag300_500_0x113C_0x02_0x01, 28.11.2017 (Flow, Promag 300 500, 0x1
HART,
Plant Resource Manager Version: R3.31Faceplate1.00.00Language neutral -
Faceplate Single, PRM_FF_FL_Promag_300500_0x103C_0x01_0x01, 15.03.2017 (Flow, Promag 300 500, 0x103
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.20Faceplate1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_FOUNDATION_Fieldbus, 15.05.2020 (Flow)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 15.05.2020 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_DP, 15.05.2020 (Flow)
PROFIBUS DP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_PA, 15.05.2020 (Flow)
PROFIBUS PA,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_ProfiNet, 15.05.2020 (Flow)
PROFINET,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-, O5P2B-
Declaration Number: HE_01038_03.18
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationGermană , Engleză -
Promag P, Promag H, Promag E, Promag 55, Promag 53, Promag 50, Promag 10, Ersatzteil, Dosimag OEM, Dosimag
Product Code: 5P5B-, 5P3B-, 5H5B-, 5H3B-, 5P1B-, 5H1B-, 53H-, 53P-, 50H-, 5P2B-, 5H2B-, 50P-, 55S-, 55H-, O5H1B-, DKH-, DK5HB-, DK5G-, 5SH-, 5RH-, 5CH-, 5BH-, 5DH-, 10H-
Declaration Number: HE_01074_01.18Manufacturer DeclarationGermană , Engleză -
Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H, Promag P
Product Code: 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5RH-, 5SH-, DDA-, DK5G-, DK5HA-, DK5HB-, DKH-, O5H1B-, O5H2B-, O5P1B-, O5P2B-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5H-, 5DH-, 5CH-, 5BH-, 55S-, 55H-, 53P-, 53H-, 50P-, 50H-, 10P-, 10H-
Declaration Number: FDA_00131_04.17FDA DeclarationGermană , Engleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Declaration Number: EC_00422_03.16EU DeclarationGermană , Engleză -
Promag E, Promag P, Promag W
Product Code: 5E1B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4C-, 5W5B-, O5E1B-, O5P1B-, O5P2B-
Declaration Number: EC_00064_05.15EU DeclarationGermană , Engleză , fr -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: O5P1B-, 5P5B-, 5P3B-, 5P2B-, 5P1B-, 55S-, 53P-, 50P-, 10P-
Declaration Number: EC_00697_03.18EU DeclarationGermană , Engleză -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-
Declaration Number: EC_00696_03.18EU DeclarationGermană , Engleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Declaration Number: EC_00409_04.16EU DeclarationGermană , Engleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Declaration Number: EC_00410_02.16EU DeclarationGermană , Engleză -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H-, 5H1B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W4D-, 5W5B-, 5W8B-, 5W8C-, DDA-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRusă -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRusă -
Dosimag, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4B-, 5W4C-, 5W5B-, 5H2B-, 5H1B-, 5H-, 5E2B-, 5E1B-, 5D4C-, 5D4B-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRusă -
Promag 10, Promag 50, Promag 51, Promag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 55H-, 55S-, 5D4C-, 5E1B-, 5H2B-, 5H3B-, 5L4B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4C-, 5W8B-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRusă -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRusă -
Promag W, Promag P, Promag H
Product Code: 5P3B-, 5H3B-, 5W3B-
Region/Country: South Korea
Approval Agency: KTL
Category: zone 1, zone 21
Protection: Ex d [ia], Ex tbExplosion Protection -
Promag H, Promag P, Promag W
Product Code: O5W3B-, 5W5B-, 5P5B-, 5P3B-, 5H5B-, 5W3B-, 5H3B-
Protection: Ex d e IIC T6...T1 Gb, Ex e [ia] IIC T6...T1 Gb, Ex ic IIC Gc, Ex nA IIC T6...T1 Gc, Ex nA IIC IIC Gc, Ex tb IIIC Txxx°C Db, Ex d [ia Ga] IIC IIC Db, Ex d e [ia Ga] IIC T6...T1 Gb, Ex d e [ia Ga] IIC IIC Gb, Ex tb [ia Da] IIIC T6 Db, Ex tb [ia Da] IIIC Txxx°C Db, IIIC Txxx°C DbExplosion ProtectionRusă -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/1/A,B,C,D,E,F,GExplosion ProtectionEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1,2Explosion ProtectionEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-, O5W5B-
Region/Country:
Approval Agency:Explosion ProtectionEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P3B-, 5W3B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 2Explosion ProtectionChineză -
Promag P, Promag H, Promag W
Product Code: 5H3B-, 5P3B-, 5W3B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 21Explosion ProtectionChineză -
Promag W, Promag P, Promag H
Product Code: 5W5B-, 5P5B-, 5H5B-, 5P3B-, 5H3B-
Region/Country: India
Approval Agency: CC(O)E
Category: zone 1Explosion ProtectionEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P3B-, 5W3B-, O5W3B-
Region/Country: Europe (ATEX)
Approval Agency: SIRA
Protection: Ex tb, Ex ia tb, Ex eb ia, Ex db eb, Ex dbExplosion ProtectionEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P3B-, 5W3B-, O5W3B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: Ex ecExplosion ProtectionEngleză -
Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promag W, Promag P, Promag H
Product Code: 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, O5W3B-, O8E3B-, O8E5B-, O8F3B-, O8F5B-, O8O3B-, O8O5B-, O8Q3B-, O8Q5B-, O8X3B-, O8X5B-, 8O5B-, 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, 8A3B-, 8A3C-, 8A5B-, 8A5C-, 8E3B-, 8E5B-, 8F3B-, 8F5B-, 8H3B-, 8H5B-, 8I3B-, 8I5B-, 8O3B-
Region/Country: Ukrain
Approval Agency: DVSZVE
Category: zone 1, zone 21Explosion Protection -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d IIC T6...T1 Gb, Ex ia IIC T6...T1 Gb, Ex nA IIC T6...T1 Gc, Ex nA IIC IIC Gc, Ex tb IIIC Txxx°C Db, Ex d [ia Ga] IIC IIC Gb, Ex d e [ia Ga] IIC T6...T1 Gb, Ex d e [ia Ga] IIC IIC Gb, Ex tb [ia Da] IIIC Txxx°C Db, IIIC Txxx°C DbExplosion ProtectionRusă -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 1, zone 21
Protection: Ex tb, Ex eb ia, Ex db eb, Ex ec, Ex dbExplosion ProtectionPortugheză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, O5W3B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,DExplosion ProtectionEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P3B-, 5W3B-, O5W3B-
Region/Country: International (IECEx)
Approval Agency: CSA
Protection: Ex tb, Ex db eb, Ex dbExplosion ProtectionEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Brazil
Approval Agency: TÜV
Category: zone 2
Protection: Ex ec, Ex tbExplosion ProtectionPortugheză -
Promag H, Promag P
Product Code: 5H3B-, 5P3B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 21Explosion ProtectionChineză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: USA, Canada
Approval Agency: CSA
Category: I/2/A,B,C,D T6...T1, I/2/A,B,C,D A,B,C,D, I/2/A,B,C,DExplosion ProtectionEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P3B-, 5W3B-
Region/Country: Japan
Approval Agency: CMLExplosion ProtectionJaponeză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I,II,III/1/A,B,C,D,E,F,G T6...T1, I/zone 1Explosion ProtectionEngleză -
Promag W, Promag P, Promag H
Product Code: 5W5B-, 5P5B-, 5H5B-, 5P3B-, 5H3B-
Region/Country: South Africa
Approval Agency: SABS
Category: zone 1, zone 2, zone 0, zone 21,22Explosion ProtectionEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P3B-, 5W3B-
Region/Country: China
Approval Agency: NEPSI
Category: zone 1, zone 21Explosion ProtectionChineză -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag L, Promag P, Promag W
Product Code: 5L4B-, 5L4C-, 5L8B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5P1B-, O5P2B-, O5W1B-, 10D-, 10L-, 10P-, 10W-, 50D-, 50L-, 50P-, 50W-, 51P-, 51W-, 53P-, 53W-, 5D4B-, 5D4C-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.05.00Fieldbus ConformanceEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: FieldComm Group
Software Version: 01.01.01Fieldbus ConformanceEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: ODVA
Software Version: 01.00.04Fieldbus ConformanceEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P3B-, 5W3B-
Region/Country: International
Approval Agency: OPC Foundation
Software Version: 01.01.03Fieldbus ConformanceEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: 01.01.00Fieldbus ConformanceEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: FieldComm GroupFieldbus ConformanceEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W5B-
Region/Country: International
Approval Agency: PI, PROFIBUS InternationalFieldbus ConformanceEngleză -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRusă -
Dosimag OEM, Promag 53, Promag H, Promag P, Promag W
Product Code: 5W5B-, 5W3B-, 5P5B-, 5P3B-, 5P1B-, 5H5B-, 5H3B-, 5H1B-, 5BH-, 53W-, 53P-, 53H-
Region/Country: USA
Approval Agency: NTEP
Approval Number: NTEP 06-019MetrologyEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.A_66478/1MetrologyRusă -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-, 5H1B-
Region/Country: International
Approval Agency: LRMarineEngleză -
Promag H, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: ABSMarineEngleză -
Promag P, Promag W
Product Code: 5P3B-, 5P5B-, 5W5B-, 5W3B-, O5W3B-, O5W5B-
Region/Country: International
Approval Agency: DNVGLMarineEngleză -
Promag H, Promag P, Promag W
Product Code: 5H1B-, 5H3B-, 5H5B-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency:MarineEngleză -
Promag H, Promag P, Promag W
Product Code: 5H1B-, 5H3B-, 5H5B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: RM RSMarineRusă -
Promag P, Promag W
Product Code: 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency: BVMarineEngleză -
Promag H, Promag P, Promag W
Region/Country:
Heartbeat TechnologyGermană , Engleză
Accesorii / Piese de schimb
-
-
Nr 31 Order code 71323007
Kit power supply, 100-230VAC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323008
Kit power supply, 24VDC, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing, electronic compartment.
-
Nr 31 Order code 71323009
Kit pow.supply,100-230VAC/24VDC, Non-haz
Usage: Promag/Promass/Prosonic Flow/ t-mass 300/500 digital, Non-haz, Zone 2, transmitter housing, electronic compartment.
-
-
-
Nr 33 Order code XPD0027-
-
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 34 Order code XPD0037-
-
-
-
Nr 37 Order code 71323010
Kit module cartridge, 300/500, Ex
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
Nr 37 Order code 71323011
Kit module cartridge, 300, Non-haz
Usage: transmitter housing, electronic compartment. Consists of: module cartridge incl. interconnection board.
-
-
-
Nr 35 Order code XPD0038-
-
-
-
Nr 46 Order code 71323005
Kit ISEM ribbon cable, 300/500
Usage: Promag/Promass 300/500, t-mass 300, transmitter housing.
-
-
-
Nr 50 Order code XPD0031-
-
-
-
Nr 45 Order code 71323073
Kit conn.terminal option A, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323074
Kit conn.terminal option B, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option B = EtherNet, PROFINET. Consists of: 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71327818
Kit conn.terminal option C, 300, Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 1x connection terminal 2-Pol., 1x connection terminal 3-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323075
Kit conn.terminal option A, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, FOUNDATION Fieldbus. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
Nr 45 Order code 71323076
Kit conn.terminal option B, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: 2x connection terminal 2-Pol.
-
Nr 45 Order code 71327819
Kit conn.terminal option C, 300/500, Ex
Usage: transmitter housing Alu/cast, connection compartment. Option C = PROFIBUS DP, Modbus RS485. Consists of: 2x connection terminal 2-Pol., 1x connection terminal 4-Pol.
-
-
-
Nr 49 Order code 71323079
Kit terminal, transm.,remote display,300
Usage: transmitter housing Alu/cast, connection compartment with remote display DKX001. Consists of: 1x connection terminal 4-Pol.
-
-
-
Nr 20 Order code 71323016
Kit cover, sight glass, Alu,Non-haz/Exde
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag/Promass 300/500, transmitter housing Alu, Ex. Consists of: cover sight glass Alu, O-Ring 110.7x3.53 HNBR.
-
-
-
Nr 21 Order code 71323018
Kit cover, blind, Alu, Non-haz/Exde
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 HNBR.
-
-
-
Nr 20 Order code 71323020
Kit cover, sight glass, Alu, Exd
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, sight glass, O-Ring 110.7x3.53 HNBR.
-
-
-
Nr 21 Order code 71323022
Kit cover, blind, Alu, Exd
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 110,7x3,53 HNBR.
-
-
-
Nr 70 Order code 71323026
Kit cover gasket, sight glass/blind
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast. Consists of: 10x O-Ring 110.7x3.53 HNBR.
-
-
-
Nr 22 Order code 71323028
Kit cover, electr.compart., Alu, Non-haz
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Consists of: cover Alu, O-Ring 117,1x3,53 HNBR.
-
-
-
Nr 74 Order code 71323030
Kit cover gasket,electr.compart.,Non-haz
Usage: Promag/Promass/Prosonic Flow/t-mass 300, transmitter housing Alu, Non-haz. Consists of: 10x O-Ring 117,1x3,53 HNBR.
-
-
-
Nr 22 Order code 71323032
Kit cover, electronic compart., Alu, Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu, Ex. Consists of: cover Alu, O-Ring 120,2x3,53 HNBR.
-
-
-
Nr 74 Order code 71323036
Kit cover gasket, electronic compart.,Ex
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing Alu/cast, Ex. Consists of: 10x O-Ring 120,2x3,53 HNBR.
-
-
-
Nr 28 Order code 71323044
Kit cover, remote display, Alu
Usage: Remote display DKX001, housing Alu. Consists of: cover Alu, O-Ring 88,50x3,53 HNBR.
-
-
-
Nr 76 Order code 71323048
Kit cover gasket, remote display
Usage: Remote display DKX001, housing Alu/cast. Consists of: 10x O-Ring 88,50x3,53 HNBR.
-
-
-
Nr 71 Order code 71323069
Kit interface gaskets, Promag 300/500
Usage: transmitter housing/sensor or transmitter housing/wall mount. Consists of: 5x O-Ring 88,50x3,53 HNBR for interface, 5x O-Ring 29,87x1,78 HNBR for for sensor plug.
-
-
-
Nr 11 Order code 71368488
Kit protective cover optionA,300,Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71368489
Kit protective cover optionB,300,Non-haz
Usage: transmitter housing Alu/hygienic, connection compartment. Option B = EtherNet, PROFINET. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323081
Kit protective cover option A,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option A = HART, PROFIBUS PA, PROFIBUS DP, Modbus RS485, FOUNDATION Fieldbus. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
Nr 11 Order code 71323082
Kit protective cover option B,300/500,Ex
Usage: transmitter housing Alu/cast, connection compartment. Option B = EtherNet, PROFINET. Consists of: Connection compartment protective cover, display carrier, 2x screw M4x10.
-
-
-
Nr 87 Order code 71343505
Kit weather protection cover, 300/500
Usage: Promag/Promass 300/500, Prosonic Flow/t-mass 300, transmitter housing. Consists of: weather protection cover 4404, installation material.
-
-
-
Order code 71351317
Kit wireless antenna extended range
Consists of: Connection cable in the transmitter, Ex cable entry for antenna, 1.5m cable, antenna, angle with union nut.
-
Order code 5X3BXX-
-
Order code DK5GD-
Promag, grounding disc/protection disc
Includes 1 grounding disc/protection disc
-
Order code DK5GC-
-
Order code DKX001-
Remote Display DKX001
Remote display and operating module of Proline 300 For more installation flexibility and better readability. Delivery: Depends on the selection in the indvidual product structure.
-
Order code DKX002-
Connection Cable for Remote Display
Connection Cable for Remote Display DKX001 of Proline 300.
-
Order code XPRFID-
-
-
Predecesor