Specificaţii pe scurt
-
Accuracy
Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in) -
Process temperature
-50...+200 °C
(-58...+392 °F) -
Process pressure / max. overpressure limit
Vacuum...40 bar
(Vacuum...580 psi) -
Max. measurement distance
Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK>1,9 -
Main wetted parts
Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA
Domeniu de aplicare
Levelflex FMP52 for level measurement in aggressive liquids with chemically resistant gap-free PFA-coated probe. All wetted parts are FDA listed materials. FMP52 guided radar offers maximum reliability even in case of moved surface. Levelflex FMP52 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Version with rod or rope probe.
Process connections: Flange or process connections for hygiene requirements (Tri-Clamp, 11851)
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
Accuracy: Rod probe ±2mm (0.08")
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval, 5-point linearity protocol
Avantaje
Reliable measurement even for changing product and process conditions
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Highest reliability due to new Multi-Echo Tracking evaluation
Hardware and software developed according to IEC 61508 up to SIL3
Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
World's easiest proof test for SIL and WHG saves time and costs
Clipuri video
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
-
Instrucţiuni de operare (BA)
Levelflex / Levelflex M Zentrierscheibe / Centering disk (PFA) Mounting Instructions
Versiune în limba engleză - 09/2017
Accessory
EN RO 29/09/201727/02/201425/04/201208/02/201124/09/2010Limbă:
Engleză
Versiune:
29/09/2017
Dimensiune fişier:
82.6 KB
Nume fişier:
BA00378FA2_1717.pdf
-
-
-
Instrucţiuni de operare (BA)
Levelflex FMP51, FMP52, FMP54 HART
Versiune în limba engleză - 12/2022
Guided wave radar
EN RO 13/12/202230/06/202231/07/202012/04/201816/11/2017Limbă:
Engleză
Versiune:
13/12/2022
Dimensiune fişier:
5.3 MB
Nume fişier:
BA01001FEN_2422-00.pdf
-
-
-
Informaţii tehnice (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN RO 25/03/202415/09/202328/10/202130/07/202119/06/2020Limbă:
Engleză
Versiune:
25/03/2024
Dimensiune fişier:
1.1 MB
Nume fişier:
TI00426FEN_2524.pdf
-
-
-
Informaţii tehnice (TI)
Levelflex FMP51, FMP52, FMP54
Guided wave radar
EN RO 22/02/202312/04/202231/07/202004/03/201912/04/2018Limbă:
Engleză
Versiune:
22/02/2023
Dimensiune fişier:
4.9 MB
Nume fişier:
TI01001FEN_2822-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Levelflex / Levelflex M Zentrierscheibe / Centering disk (PFA) Mounting Instructions
Accessory
EN RO 29/09/201727/02/201425/04/201208/02/201124/09/2010Limbă:
Engleză
Versiune:
29/09/2017
Dimensiune fişier:
82.6 KB
Nume fişier:
BA00378FA2_1717.pdf
-
-
-
Instrucţiuni de operare (BA)
Levelflex FMP51, FMP52, FMP54 PROFIBUS PA
Guided wave radar
EN RO 21/02/202330/06/202212/04/201816/11/201715/12/2016Limbă:
Engleză
Versiune:
21/02/2023
Dimensiune fişier:
4.7 MB
Nume fişier:
BA01006FEN_2022-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus
Guided wave radar
EN RO 21/02/202330/06/202212/04/201816/11/201715/12/2016Limbă:
Engleză
Versiune:
21/02/2023
Dimensiune fişier:
5.9 MB
Nume fişier:
BA01052FEN_0822-00.pdf
-
-
-
Instrucţiuni de operare (BA)
Levelflex FMP51, FMP52, FMP54 HART
Guided wave radar
EN RO 13/12/202230/06/202231/07/202012/04/201816/11/2017Limbă:
Engleză
Versiune:
13/12/2022
Dimensiune fişier:
5.3 MB
Nume fişier:
BA01001FEN_2422-00.pdf
-
-
-
Parametru dispozitiv (GP)
Levelflex FMP5x HART Description of Device Parameters
Guided wave radar
EN RO 28/04/201630/10/201426/02/201429/07/201101/10/2010Limbă:
Engleză
Versiune:
28/04/2016
Dimensiune fişier:
3.3 MB
Nume fişier:
GP01000FEN_1616.pdf
-
-
-
Parametru dispozitiv (GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 PROFIBUS PA Description of Device Parameters
Guided wave radar
EN RO 30/10/201404/08/2011Limbă:
Engleză
Versiune:
30/10/2014
Dimensiune fişier:
4.7 MB
Nume fişier:
GP01001FEN_1314.pdf
-
-
-
Parametru dispozitiv (GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 FOUNDATION Fieldbus Description of Device Parameters
Guided wave radar
EN RO 09/06/201527/04/2012Limbă:
Engleză
Versiune:
09/06/2015
Dimensiune fişier:
3.5 MB
Nume fişier:
GP01015FEN_0215.pdf
-
-
-
Instrucţiuni scurte (KA)
Levelflex FMP51, FMP52, FMP54 HART
Radar cu undă ghidată
EN RO 30/06/202205/04/202212/04/201817/11/201712/02/2015Limbă:
Română
Versiune:
05/04/2022
Dimensiune fişier:
1.5 MB
Nume fişier:
KA01077FRO_1922-00.pdf
-
-
-
Instrucţiuni scurte (KA)
Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus
Radar cu undă ghidată
EN RO 30/06/202205/04/202212/04/201830/11/201717/11/2017Limbă:
Română
Versiune:
05/04/2022
Dimensiune fişier:
1.3 MB
Nume fişier:
KA01107FRO_0722-00.pdf
-
-
-
Instrucţiuni scurte (KA)
Levelflex FMP51, FMP52, FMP54 PROFIBUS PA
Radar cu undă ghidată
EN RO 30/06/202205/04/202212/04/201817/11/201712/02/2015Limbă:
Română
Versiune:
05/04/2022
Dimensiune fişier:
1.3 MB
Nume fişier:
KA01079FRO_1722-00.pdf
-
-
-
Instrucţiuni scurte (KA)
Screw set for Micropilot II/M, Levelflex M, Prosonic M
Screw set for Micropilot II/M, Levelflex M, Prosonic M
EN RO 15/04/2021Limbă:
Engleză
Versiune:
15/04/2021
Dimensiune fişier:
532.2 KB
Nume fişier:
KA00512F00_A2.pdf
-
-
-
Instrucţiuni de instalare (EA)
Display module Installation Instructions
Levelflex FMP5x, Micropilot FMR5x
EN RO 08/06/2018Limbă:
Engleză
Versiune:
08/06/2018
Dimensiune fişier:
345.1 KB
Nume fişier:
EA01247FA2_0118.pdf
-
-
-
Instrucţiuni de instalare (EA)
M12 connector, IP66/68 NEMA4X/6P, ProToF Installation Instructions
Levelflex FMP5x
Micropilot FMR5x, FMR6xEN RO 01/10/2019Limbă:
Engleză
Versiune:
01/10/2019
Dimensiune fişier:
349 KB
Nume fişier:
EA01289FEN_0119.pdf
-
-
-
Instrucţiuni de instalare (EA)
Set housing security clamp Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,EN RO 31/08/201707/10/201305/01/2012Limbă:
Engleză
Versiune:
31/08/2017
Dimensiune fişier:
279.5 KB
Nume fişier:
EA00038FA2_1717.pdf
-
-
-
Instrucţiuni de instalare (EA)
Main electronics module Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x
EN RO 31/08/201714/04/201408/01/2013Limbă:
Engleză
Versiune:
31/08/2017
Dimensiune fişier:
281.5 KB
Nume fişier:
EA00041FA2_1617.pdf
-
-
-
Instrucţiuni de instalare (EA)
Replacing the display module Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50EN RO 01/09/201701/02/201724/11/201528/11/201306/04/2012Limbă:
Engleză
Versiune:
01/09/2017
Dimensiune fişier:
562.2 KB
Nume fişier:
EA00102DA2_1817.pdf
-
-
-
Instrucţiuni de instalare (EA)
Cover Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50EN RO 28/06/201828/02/201718/11/201524/02/201502/10/2013Limbă:
Engleză
Versiune:
28/06/2018
Dimensiune fişier:
517.9 KB
Nume fişier:
EA00035FA2_2018.pdf
-
-
-
Instrucţiuni de instalare (EA)
Replacing the main electronics module Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200
EN RO 01/10/201818/08/201429/06/2012Limbă:
Engleză
Versiune:
01/10/2018
Dimensiune fişier:
485.9 KB
Nume fişier:
EA00103DA2_1718.pdf
-