Specificaţii pe scurt
-
Process temperature
Max. 60 °C
(Max. 140 °F) -
Process pressure
Max. 4 bar relative
(Max. 58 psi relative)
Domeniu de aplicare
Flowfit CCA151 is a simple flow assembly for disinfection parameters such as chlorine dioxide that do not require pH compensation. Sensors installed in the acrylic glass assembly need only a sample flow as low as 5 l/h (1.32 gph) for accurate measurement. This enables precise control of disinfection processes with minimal water loss. Thanks to flexible mounting options for panels, walls and pipes, Flowfit CCA151 places the disinfection sensor at an optimal position for best measuring results.
CCA151 is a flow assembly for the measurement of disinfection parameters without pH compensation, e.g. chlorine dioxide in:
Drinking water
Utilities of all industries
Applications with low sample volumes
Avantaje
Minimum water loss: When installed in Flowfit CCA151, sensors require a sample flow as low as 5 l/h (1.32 gph) for precise chlorine dioxide measurement. Only a very small volume of water goes to waste.
Reliable measurement: Flexible mounting options allow you to position the sensor exactly where it is needed to accurately determine the chlorine dioxide content.
Cost-effective update of your installed base: Easy replacement of CCA250 thanks to identical dimensions.
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
-
Informaţii tehnice (TI)
Flowfit CCA151 Technical Information
Flow assembly for disinfection sensors CCS5xD
EN RO 19/06/2017Limbă:
Engleză
Versiune:
19/06/2017
Dimensiune fişier:
376.4 KB
Nume fişier:
TI01357CEN_0117.pdf
-
-
-
Instrucţiuni de operare (BA)
Flowfit CCA151 Operating Instructions
Flow assembly for disinfections sensors CCS5xD
EN RO 19/06/2017Limbă:
Engleză
Versiune:
19/06/2017
Dimensiune fişier:
435.8 KB
Nume fişier:
BA01785CEN_0117.pdf
-
-
-
Inovaţie (IN)
Chlordioxid-Analyse in Trink- und Prozesswasser
Sichere, effektive Desinfektion mit Memosens CCS50D
Limbă:
Germană
Versiune:
27/10/2017
Dimensiune fişier:
743.8 KB
Nume fişier:
IN01114CDE_0117.pdf
-
-
-
Inovaţie (IN)
Chlorine dioxide measurement in drinking and process water
Safe and efficient disinfection with Memosens CCS50D
Limbă:
Engleză
Versiune:
27/10/2017
Dimensiune fişier:
644.7 KB
Nume fişier:
IN01114CEN_0117.pdf
-
-
-
Declaraţia producătorului
Product family: Flowfit
Product root: CCA151-
Declaration number: HE_01014_01.18Limbă:
Engleză
Versiune:
19/06/2018
Dimensiune fişier:
33.8 KB
Nume fişier:
HE_01014_01.18_TSE_BSE_CCA151.pdf
-
-
-
Text de licitaţie
Flowfit CCA151
Durchflussarmatur für Chlordioxid-Sensoren zum Einbau in Rohrleitungen
(Bypass)Limbă:
Germană
Versiune:
04/01/2018
Dimensiune fişier:
14.7 KB
Nume fişier: