Introduceţi cel puţin 2 caractere pentru a începe căutarea.

Flow assembly for chlorine dioxide sensors Flowfit CCA151

Flowfit CCA151: Flow assembly for chlorine dioxide sensors ©Endress+Hauser
Flowfit CCA151 flow assembly with Memosens CCS50D chlorine dioxide sensor installed ©Endress+Hauser

Simple assembly for drinking and process water applications

Flowfit CCA151 is a simple flow assembly for disinfection parameters such as chlorine dioxide that do not require pH compensation. Sensors installed in the acrylic glass assembly need only a sample flow as low as 5 l/h (1.32 gph) for accurate measurement. This enables precise control of disinfection processes with minimal water loss. Thanks to flexible mounting options for panels, walls and pipes, Flowfit CCA151 places the disinfection sensor at an optimal position for best measuring results.

  • Produse simple

  • Ușor de ales, instalat și administrat

Excelenţă tehnică

Simplitate

  • Produse clasice

  • Fiabile, robuste și ușor de întreținut

Excelenţă tehnică

Simplitate

  • Produse superioare

  • Extrem de funcțional și convenabil

Excelenţă tehnică

Simplitate

  • Produse de specialitate

  • Conceput pentru aplicatii solicitante

Excelenţă tehnică

Simplitate

Variabil

Colecții FLEX Excelenţă tehnică Simplitate
  • F
  • L
  • E
  • X

Colecție Fundamental

Îndepliniți-vă nevoile esențiale de măsurare

Excelenţă tehnică
Simplitate
  • F
  • L
  • E
  • X

Selecţie Lean

Gestionați-vă cu ușurință procesele de bază

Excelenţă tehnică
Simplitate
  • F
  • L
  • E
  • X

Colecție Extended

Optimizați-vă procesele cu tehnologii inovatoare

Excelenţă tehnică
Simplitate
  • F
  • L
  • E
  • X

Colecție Xpert

Stăpâniţi cele mai dificile aplicaţii

Excelenţă tehnică
Simplitate

Variabil

  • Specificaţii pe scurt

    • Process temperature

      Max. 60 °C
      (Max. 140 °F)

    • Process pressure

      Max. 4 bar relative
      (Max. 58 psi relative)

Selectare rapidă

Alegeţi dintre opţiunile noastre sugerate
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

sau

Configurare individuală

Selectaţi în continuare dintre toate opţiunile posibile
  • Avantaje

    • Minimum water loss: When installed in Flowfit CCA151, sensors require a sample flow as low as 5 l/h (1.32 gph) for precise chlorine dioxide measurement. Only a very small volume of water goes to waste.

    • Reliable measurement: Flexible mounting options...

  • Domeniu de aplicare

    CCA151 is a flow assembly for the measurement of disinfection parameters without pH compensation, e.g. chlorine dioxide in:

    • Drinking water

    • Utilities of all industries

    • Applications with low sample volumes

Caracteristici şi specificaţii

Înapoi

Details

  • Measuring principle

    Free chlorine

  • Application

    Drinking water
    Utilities of all industries
    For low sample flow

  • Characteristic

    Flow through assembly for one disinfection sensor

  • Design

    Flow assembly with direct inflow to the membran

  • Material

    Plexiglas (PMMA)

  • Dimension

    85 mm x 85 mm x 220 mm
    (3.35 inch x 3.35 inch x 8.64 inch)

  • Process temperature

    Max. 60 °C
    (Max. 140 °F)

  • Process pressure

    Max. 4 bar relative
    (Max. 58 psi relative)

Documente / Manuale / Software

Accesorii / Piese de schimb

Nr
Order code
Specification