Proline Promass I 300 for the chemical industry
Proline Promass I 300 for the food & beverages industries
Mass flow (liquid): ±0.10 %Volume flow (liquid): ±0.10 %Mass flow (gas): ±0.50 %Density (liquid): ±0.0005 g/cm³
0 to 180 000 kg/h (0 to 6600 lb/min)
–50 to +150 °C (–58 to +302 °F)
PN 100, Class 600, 63K
Measuring tube: Titanium grade 9Connection: Titanium grade 2
The straight single-tube design of Promass I provides in-line viscosity measurement in addition to mass flow, density and temperature measurement. With its compact transmitter Promass I 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.
Measuring principle operates independently of physical fluid properties such as viscosity or density
Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment
Device properties
Straight, easy-to-clean single-tube system
TMB technology
Measuring tube made of Titanium
Compact dual-compartment housing with up to 3 I/Os
Backlit display with touch control and WLAN access
Remote display available
Energy-saving – full bore design enables minimal pressure loss
Fewer process measuring points – multivariable measurement (flow, density, temperature)
Space-saving installation – no in-/outlet run needs
Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Produse de specialitate
Excelenţă tehnică
Simplitate
Variabil
Produse simple
Produse clasice
Produse superioare
Colecție Fundamental
Îndepliniți-vă nevoile esențiale de măsurare
Selecţie Lean
Gestionați-vă cu ușurință procesele de bază
Colecție Extended
Optimizați-vă procesele cu tehnologii inovatoare
Colecție Xpert
Stăpâniţi cele mai dificile aplicaţii
Thanks to inline viscosity measurement, a ketchup producer can continuously control the quality during production, save time waiting for lab results and avoid product losses and reduce unplanned costs
Configurare pentru descărcarea desenelor CAD ale acestui produs
Coriolis
Combines in-line viscosity and flow measurement with a compact, easily accessible transmitter..Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Energy‐saving – full-bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.Straight, easy-to-clean single-tube system. TMB technology. Measuring tube made of Titanium.
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
DN 8 to 80 (⅜ to 3")
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
Standard: –40 to +60 °C (–40 to +140 °F)Option: –50 to +60 °C (–58 to +140 °F)
1.4301/1.4307 (304L), corrosion resistant
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
IP66/67, type 4X enclosureIP69
4-line backlit display with touch control (operation from outside)Configuration via local display and operating tools possibleRemote display available
3 outputs:4-20 mA HART (active/passive)4-20 mA (active/passive)Pulse/frequency/switch output (active/passive)Relay output
Status input4-20 mA input
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
DC 24 VAC 100 to 230 VAC 100 to 230 V / DC 24 V (non-hazardous area)
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC
CE, C-tick, EAC marking
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
PED, CRN
3.1 material
3-A, EHEDG, cGMP
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
0 to 180 000 kg/h (0 to 6615 lb/min)
1.4301 (304), corrosion resistant
Standard: IP66/67, Type 4X enclosureOption: IP69
" IP66/67, type 4X enclosureIP69"
Status input 4-20 mA input
Versiune în limba engleză - 11/2024
New version available in English
Coriolis flowmeter
Limbă:
Engleză
Versiune:
01/11/2024
Dimensiune fişier:
10.9 MB
Nume fişier:
TI01274DEN_0924-00.pdf
Coriolis flowmeterPROFINET over Ethernet-APL
7.3 MB
BA02112DEN_0224-00.pdf
Coriolis flowmeterPROFIBUS DP
6.9 MB
BA01859DEN_0324-00.pdf
Coriolis flowmeterPROFINET
9.6 MB
BA01741DEN_0524-00.pdf
Coriolis flowmeterEtherNet/IP
7.9 MB
BA01730DEN_0324-00.pdf
01/08/2018
2.4 MB
GP01094DEN_0218.pdf
<%message%>
Accesorii
Produse asociate
Utilizăm module cookie pentru a optimiza experienţa dumneavoastră de navigare şi pentru a colecta date statistice în vederea optimizării funcţionalităţii site-ului web şi pentru a vă oferi reclame sau conţinuturi personalizate.
Prin selectarea opţiunii „Acceptare totală”, vă oferiţi consimţământul privind utilizarea modulelor cookie. Pentru detalii suplimentare, vă rugăm să citiţi Politica noastră privind modulele cookie .
Headline h4