Bioprocessing Raman spectroscopy calibration and verification kit for the Raman flow assembly

Raman calibration and verification kits

Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability

KRCAL
Please Wait (spinning wheel)
Se încarcă preţul
Preţurile sunt temporar indisponibile
Price on request
Filtrare măsurători / aplicaţie
Activitate de măsurare / aplicaţie

Configurare pentru descărcarea desenelor CAD ale acestui produs

  • Measuring principle

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-10 (with bio multi optic)

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm

  • Measuring principle

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-10 (with Raman flow bench)

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm

  • Measuring principle

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-46

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm