Proline Promag P 100
Electromagnetic flowmeter
The flowmeter for highest medium temperatures with an ultra-compact transmitter
Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Its ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration, making Promag P 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology ensures compliance and process safety at all times.
- F
- L
- E
- X
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
Specificaţii pe scurt
-
Max. measurement error
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s -
Measuring range
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
-
Medium temperature range
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) -
Max. process pressure
PN 40, Class 300, 20K
-
Wetted materials
Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803)
-
Selectare rapidă
Configurare individuală
-
Avantaje
Versatile applications – wide variety of wetted materials
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
Space-saving transmitter – full functionality on the smallest footprint
Time-...
-
Domeniu de aplicare
The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures
Device properties
Nominal diameter: max....
Documente / Manuale / Software
-
Proline Promag P 100
Technical Information
Electromagnetic flowmeter
The flowmeter for highest medium temperatures with an ultra-compact
transmitterTechnical Information (TI) -
Proline Promag P 100
HART
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 100
EtherNet/IP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 100
Modbus RS485
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 100
PROFIBUS DP
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag P 100
PROFINET
Operating Instructions
Electromagnetic flowmeter
Operating Instruction (BA) -
Proline Promag 100
PROFIBUS DP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 100
EtherNet/IP
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 100
PROFINET
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 100
Modbus RS485
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline Promag 100
HART
Description of Device Parameters
Electromagnetic flowmeter
Device Parameter (GP) -
Proline 100
PROFINET
Brief Operating Instructions
Part 2 of 2
TransmitterShort Instruction (KA)12/15Engleză -
Proline Promag P
Brief Operating Instructions
Proline Promag P
Electromagnetic sensorShort Instruction (KA)10/17Engleză -
Proline Promag P 100
Brief Operating Instructions
Electromagnetic flowmeter
Short Instruction (KA)09/15Engleză -
Proline Promag
Brief Operating Instructions
Proline Promag
Part 1 of 2
Electromagnetic sensorShort Instruction (KA)04/17Engleză -
Replacing the Electronics Module
Installation Instructions
Promag 100
Installation Instructions (EA) -
Installing ground disks
Promag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
Installation Instructions (EA) -
Replacing Spare Parts
Promag, Promass 100, CNG-, LNG-, LPGmass, Promag 400 Index C, Proline
300, 500, 500-digital, Prosonic Flow E 100, Prosonic Flow E He
at, Prosonic Flow, t-mass 300, 500-digitalInstallation Instructions (EA) -
Replacing Display module, non Ex, Zone 2, Class 1 Div. 2
Installation Instructions
Promass 100, Promag 100, Prosonic Flow E 100
Installation Instructions (EA) -
Safety Instructions for Spare Parts
Installation Instructions
Flowmeter
Installation Instructions (EA) -
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150Installation Instructions (EA) -
Replacing the Seal Housing
Installation Instructions
Promag 100, Promag 500-digital
Installation Instructions (EA) -
Replacing Transmitter
Proline Promag H, P, 100
Installation Instructions
Installation Instructions (EA) -
Replacing Small parts
Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400 Index C,
Prosonic Flow E 100, Prosonic Flow E Heat, Prosonic Flow, t-mass
500-digitalInstallation Instructions (EA) -
Proline Promag 100
ATEX:
II3G Ex nA IIC T6…T1
IECEx:
Zone 2 Ex nA IIC T6…T1
Safety Instructions
Documentation for hazardous areas
Ex Safety Instructions (XA) -
Proline Promag 100
INMETRO:
Ex nA IIC T6…T1
Safety Instructions
Documentation for hazardous area
Ex Safety Instructions (XA) -
Information on the Pressure Equipment Directive
Proline flowmeters
Special Documentation
Proline flowmeters
Special Documentation (SD) -
Change of Directives
Special Documentation
Change of Directives
Special Documentation (SD) -
Proline Promag
Information on the Pressure Equipment Directive
Special Documentation
Electromagnetic flow measuring system
Special Documentation (SD) -
Proline Promag 100
Special Documentation
Heartbeat Verification + Monitoring application package
Special Documentation (SD) -
Proline Promag/Promass
EtherNet/IP
System integration
Special Documentation (SD) -
Proline Promag 100, Promass 100
Modbus RS485
Transmitter terminal assignment
Special Documentation
Transmitter terminal assignment
Special Documentation (SD) -
Proline Promag 100
PROFINET
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 100
PROFIBUS DP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 100
HART
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 100
Heartbeat Technology Application Package
Supplementary documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 100
EtherNet/IP
Web server
Special Documentation
Web server
Special Documentation (SD) -
Proline Promag 100
Register information Modbus RS485
Special Documentation
Electromagnetic flowmeter
Special Documentation (SD) -
Proline Promag 100
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 100 EtherNet/IP: 1.01.01Manufacturer Information (MI) -
Proline Promag 100
Manufacturer information regarding firmware updates (NE 53)
New firmware version:
Promag 100 Modbus RS485: 1.01.01Manufacturer Information (MI) -
Proline Promag 100
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 100 PROFIBUS DP: 1.01.01Manufacturer Information (MI) -
Proline Promag 100
Manufacturer information regarding firmware
updates (NE 53)
New firmware version:
Promag 100 HART: 1.01.01Manufacturer Information (MI) -
Industrial Ethernet for Proline flowmeters
The system integration of the future
Innovations (IN)12/17Engleză -
Industrial Ethernet für Proline Durchflussmessgeräte
Die Systemintegration der Zukunft
Innovations (IN)12/17Germană -
Proline Promass 100 / Promag 100
Der Durchfluss-Spezialist im Kompaktdesign
Volle Funktionalität auf engstem RaumInnovations (IN)11/14Germană -
Proline Promass 100 / Promag 100
The flow specialists in a compact design
Full functionality in a small packageInnovations (IN)11/14Engleză -
Ethernet industriel pour débitmètres Proline
L'intégration système du futur
Innovations (IN)10/15fr -
Proline Promass 100 / Promag 100
Zaawansowane możliwości w kompaktowym wydaniu.
Rodzina kompaktowych przepływomierzy masowych
i elektromagnetycznychInnovations (IN)06/12Poloneză -
GSD Single, GSD_PN_FL_Promag100_0x843A_0x01_0x02, 11.08.2020 (Flow, Promag 100, 0x843A)
PROFINET,
PROFINET System Version: AnyGeneral Station Description (GSD)1.00.01Language neutral -
GSD Single, GSD_DP_FL_Promag100_0x1560_0x01_0x01, 14.04.2014 (Flow, Proma
g 100, 0x1560)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_DP_FL_Promag100_0x1560_0x02_0x01, 30.06.2015 (Flow, Proma
g 100)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDS Single, EDS_EH_EIP_FL_Promag_100_0x103A_0x02_0x01, 23.10.2015 (Flow, Promag 100)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)2.1Language neutral -
EDS Single, EDS_EH_EIP_FL_Promag_100_0x103A_0x01_0x01, 23.10.2015 (Flow,
Promag 100)
EtherNet/IP,
EtherNet IP System Version: AnyElectronic Data Sheet (EDS)1.1Language neutral -
EDD Single, PDM_HART_FL_Promag100_0x003A_0x01_0x01, 31.03.2014 (Flow, Pro
mag 100, 0x003A)
HART,
PDM Version: 6.1, 8.0.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag100_0x003A_0x01_0x01, 20.08.2019 (Flow, Promag 100, 0x003A)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag100_0x003A_0x01_0x01, 31.03.2014 (Flow, Pro
mag 100, 0x003A)
HART,
Field Device Manager Version: R410Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, FDM_HART_FL_Promag100_0x003A_0x02_0x01, 16.03.2015 (Flow, Promag 100, 0x003A)
HART,
Field Device Manager Version: R430.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag100_0x1560_0x02_0x01, 17.06.2015 (Flow, Proma
g 100)
PROFIBUS DP,
PDM Version: 6.1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS11_HART_FL_Promag100_0x003A_0x02_0x01, 20.08.2019 (Flow, Promag 100, 0x003A)
HART,
AMS Version: 10.5, 11.0, 11.1, 11.5, 12.0Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_DP_FL_Promag100_0x1560_0x01_0x01, 28.03.2014 (Flow, Proma
g 100, 0x1560)
PROFIBUS DP,
PDM Version: 6.1, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag100_0x003A_0x02_0x01, 20.08.2019 (Flow, Promag 100, 0x003A)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS12_HART_FL_Promag100_0x003A_0x01_0x01, 20.08.2019 (Flow, Promag 100, 0x003A)
HART,
AMS Version: 12.0, 12.5, 13.0, 13.1, 13.5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_FL_Promag100_0x003A_0x02_0x01, 16.03.2015 (Flow, Promag 100, 0x003A)
HART,
PDM Version: 6.1, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, Promag100_5x1B_DP_FW1_01_zz_Dev_Rev_2, 19.10.2020 (Flow, Promag 100, 0x1560)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.7.0.86Language neutral -
DTM Single, Promag100_5x1B_PNIO-CDIE_FW_1_00_zz_Dev_Rev_1, 05.11.2020 (Flow, Promag 100, 0x843A)
PROFINET,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.0.37Language neutral -
DTM Single, Promag_100_5x1B_EIP_FW_1_01_zz_Dev_Rev_2, 05.11.2020 (Flow, Promag 100, 0x103A)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.0.175Language neutral -
DTM Single, Promag_100_5x1B_EIP-CDIE_FW_1_01_zz_Dev_Rev_2, 05.11.2020 (Flow, Promag 100)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.0.174Language neutral -
DTM Single, Promag_100_5x1B_MR4_FW_1_01_zz_Dev_Rev_2, 06.11.2020 (Flow, Promag 100, 0x643A)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.1.354Language neutral -
DTM Single, Promag_100_5x1B_MR4-CDIS_FW_1_01_zz_Dev_Rev_2, 06.11.2020 (Flow, Promag 100, 0x643A)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.1.354Language neutral -
DTM Single, Promag100_5x1B_HART_FW1_01_zz_Dev_Rev_02, 27.10.2020 (Flow, Promag 100, 0x113A)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.3.0.201Language neutral -
DTM Single, Promag100_5x1Bxx_DP_FW1_00_zz_Dev_Rev_1, 19.10.2020 (Flow, Promag 100, 0x1560)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.1.0.55Language neutral -
DTM Single, Promag_100_5x1B_MR4_FW_1_00_zz_Dev_Rev_1, 06.11.2020 (Flow, Promag 100, 0x643A)
Modbus RS485,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.0.0.300Language neutral -
DTM Single, Promag100_5x1B_HART_FW1_00_zz_Dev_Rev_01, 23.10.2020 (Flow, Promag 100, 0x003A)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00
FieldMate Version: 2.05
Plant Resource Manager Version: R3.10Device Type Manager (DTM)1.0.0.161Language neutral -
DTM Single, Promag_100_5x1B_EIP_FW_1_00_zz_Dev_Rev_1, 05.11.2020 (Flow, Promag 100, 0x103A)
EtherNet/IP,
DeviceCare Version: 1.06.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.0.0.135Language neutral -
AOP Single, RS_EIP_FL_Promag100_5x1B_0x103A_0x02_0x01, 20.11.2018 (Flow, Promag 100, 0x103A)
EtherNet/IP,
RA RSLogix 5000 Version: V15 and laterAdd On Profile (AOP)1.65.01Language neutral -
Faceplate Library, PRM_HART_Package_Flow_1_08_00, 22.07.2015 (Flow)
HART,
Plant Resource Manager Version: R3.02, R3.05, R3.10, R3.11, R3.12Faceplate1.08.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag100_0x003A_0x01_0x01, 31.03.2014 (Flo
w, Promag 100, 0x003A)
HART,
Plant Resource Manager Version: R3.10Faceplate1.00.00Language neutral -
Faceplate Single, PRM_HART_FL_Promag100_0x003A_0x02_0x01, 16.03.2015 (Flow, Promag 100, 0x003A)
HART,
Plant Resource Manager Version: R3.11Faceplate1.00.00Language neutral -
Note Single, Release_Notes_for_AMS_HART_Flow, 15.06.2018 (Flow)
HART,
AMS Version: AnyNote1.00.00Language neutral -
Verification DTM Library, VerificationDTM_FLOW_EIP, 15.05.2020 (Flow)
EtherNet/IP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_ProfiNet, 15.05.2020 (Flow)
PROFINET,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_PROFIBUS_DP, 15.05.2020 (Flow)
PROFIBUS DP,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_Modbus_RS485, 15.05.2020 (Flow)
Modbus RS485,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Verification DTM Library, VerificationDTM_FLOW_HART, 15.05.2020 (Flow)
HART,
DeviceCare Version: 1.06.00
FieldCare Version: 2.13.00Verification DTM1.06.05Language neutral -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-, O5P2B-
Declaration Number: HE_01038_03.18
Manufacturer Specification: Food hygiene, 1935/2004Manufacturer DeclarationGermană , Engleză -
Promag P, Promag H, Promag E, Promag 55, Promag 53, Promag 50, Promag 10, Ersatzteil, Dosimag OEM, Dosimag
Product Code: 5P5B-, 5P3B-, 5H5B-, 5H3B-, 5P1B-, 5H1B-, 53H-, 53P-, 50H-, 5P2B-, 5H2B-, 50P-, 55S-, 55H-, O5H1B-, DKH-, DK5HB-, DK5G-, 5SH-, 5RH-, 5CH-, 5BH-, 5DH-, 10H-
Declaration Number: HE_01074_01.18Manufacturer DeclarationGermană , Engleză -
Dosimag, Dosimag OEM, Ersatzteil, Promag 10, Promag 50, Promag 53, Promag 55, Promag H, Promag P
Product Code: 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5RH-, 5SH-, DDA-, DK5G-, DK5HA-, DK5HB-, DKH-, O5H1B-, O5H2B-, O5P1B-, O5P2B-, 5H5B-, 5H3B-, 5H2B-, 5H1B-, 5H-, 5DH-, 5CH-, 5BH-, 55S-, 55H-, 53P-, 53H-, 50P-, 50H-, 10P-, 10H-
Declaration Number: FDA_00131_04.17FDA DeclarationGermană , Engleză -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5H1B-, 5P1B-
Declaration Number: EC_00281_01.16EU DeclarationGermană , Engleză , fr -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5H1B-, 5P1B-
Declaration Number: EC_00282_02.16EU DeclarationGermană , Engleză , fr -
Promag E, Promag P, Promag W
Product Code: 5E1B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4C-, 5W5B-, O5E1B-, O5P1B-, O5P2B-
Declaration Number: EC_00064_05.15EU DeclarationGermană , Engleză , fr -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: 10P-, 50P-, 53P-, 55S-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, O5P1B-
Declaration Number: EC_00696_03.18EU DeclarationGermană , Engleză -
Promag 10, Promag 50, Promag 53, Promag 55, Promag P
Product Code: O5P1B-, 5P5B-, 5P3B-, 5P2B-, 5P1B-, 55S-, 53P-, 50P-, 10P-
Declaration Number: EC_00697_03.18EU DeclarationGermană , Engleză -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag, Promass X, Promass S, Promass Q, Promass P, Promass O, Promass I, Promass H, Promass F, Promass E, Promass A, Promass 84, Promass 83, Promass 80, Dosimass OEM
Product Code: 5D4C-, 5P5B-, 5W5B-, 5P3B-, 5H5B-, 5W3B-, 5W4C-, 5L4C-, 53P-, 53W-, 5P1B-, 5H1B-, 5H3B-, 50W-, 50P-, 50H-, 53H-, 5E1B-, 55S-, 5P2B-, 53L-, 55H-, 5H2B-, 50L-, 53E-, 50D-, 50E-, 51W-, 5H-, 5L4B-, 5W4D-, 5W4B-, 5W8B-, 5W8C-, DDA-, 5D4B-, 10D-, 10E-, 10H-, 10P-, 10W-, 10L-, 51P-, 8E5B-, 8F1B-, 8F2B-, 8F3B-, 8H1B-, 8H3B-, 8H5B-, 8I1B-, 8I3B-, 8I5B-, 8O1B-, 8O3B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 80A-, 80E-, 80F-, 80I-, 80P-, 80S-, 83A-, 83E-, 83F-, 83H-, 83I-, 83P-, 83S-, 83X-, 84F-, 84X-, 8A1B-, 8A3B-, 8A5B-, 8BE-, 8E1B-, 8E2B-, 8E3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02246/20MiscellaneousRusă -
Promass K, Promass O, Promass P, Promass Q, Promass S, Promass X, Prosonic Flow 91, Prosonic Flow 92, Prosonic Flow 93, Prosonic Flow G, Prowirl D, Prowirl F, Prowirl O, Prowirl R, t-mass, t-mass A, t-mass B, T-MASS F, T-MASS I, Promass I, CNGmass, Dosimag, Dosimass, LNGmass, LPGmass, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W, Promass 40, Promass 80, Promass 83, Promass 84, Promass E, Promass F, Promass H
Product Code: 8I3B-, 8I1B-, 8H5B-, 8H3B-, 8F5B-, 8F3B-, 8F2B-, 8F1B-, 8E5B-, 8E3B-, 8E2C-, 8E2B-, 8E1C-, 8E1B-, 8E-, 84X-, 84F-, 83X-, 83F-, 80F-, 7R2C-, 8I5B-, 8K1B-, 8O3B-, 8O5B-, 8P1B-, 8P3B-, 8P5B-, 8Q3B-, 8Q5B-, 8S1B-, 8S1C-, 8S3B-, 8S5B-, 8X3B-, 8X5B-, 91W-, 92F-, 93C-, 93W-, 9G3B-, 9G5B-, DDA-, 7R2B-, 10D-, 10E-, 10H-, 10L-, 10P-, 10W-, 40E-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 7O2C-, 7O2B-, 7F2C-, 7F2B-, 7D2C-, 7D2B-, 6I5B-, 6I3B-, 6F5B-, 6F3B-, 6BAB-, 6AAB-, 65I-, 65F-, 5W8C-, 5W8B-, 5W5B-, 5W4D-, 5W4C-, 5W4B-, 5W3B-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRusă -
Promag 10, Promag 50, Promag 51, Promag 55, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 55H-, 55S-, 5D4C-, 5E1B-, 5H2B-, 5H3B-, 5L4B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4C-, 5W8B-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC RU D-CH.MU62.B.02333MiscellaneousRusă -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 53L-, 53P-, 53W-, 5D4B-, 5D4C-, 5E1B-, 5E2B-, 5H1B-, 5H2B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5W4B-, 5W4C-, 5W8B-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 126MiscellaneousRusă -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10, Dosimag
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H-, 5H1B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W4D-, 5W5B-, 5W8B-, 5W8C-, DDA-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 50D-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-CH.AD07.B.02228/20MiscellaneousRusă -
Dosimag, Promag 10, Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W3B-, 5W4B-, 5W4C-, 5W5B-, 5H2B-, 5H1B-, 5H-, 5E2B-, 5E1B-, 5D4C-, 5D4B-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Russia (TR CU)
Approval Number: EAEC N RU D-CH.AD07.B.03271/20MiscellaneousRusă -
Promag P, Promag H, Promag W, Promag D, Promag E, Promag L
Product Code: 5P1B-, 5E1B-, 5H1B-, O5E1B-, O5H1B-, O5P1B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D, I/zone 2
Protection: AEx/Ex nA IICExplosion ProtectionEngleză -
Promag D, Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: 5E1B-, 5H1B-, 5P1B-, O5E1B-, O5H1B-, O5P1B-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D, I/zone 2
Protection: AEx/Ex nA IIC T6...T1 GcExplosion ProtectionEngleză -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5P1B-, O5E1B-, O5H1B-, O5P1B-
Region/Country: Russia
Protection: Ex nA IIC T6...T1 Gc, Ex nA IIC IIC GcExplosion ProtectionRusă -
Promag E, Promag H, Promag L, Promag P, Promag W
Product Code: O5W1B-, O5P1B-, O5L1B-, O5H1B-, O5E1B-, 5W1B-, 5P1B-, 5L1B-, 5H1B-, 5E1B-
Region/Country: Brazil
Approval Agency: INMETRO
Category: zone 2
Protection: Ex nAExplosion ProtectionEngleză -
Promag E, Promag P, Promag W, Promag H, Promag L
Product Code: O5W1B-, 5P1B-, 5H1B-, 5E1B-, O5P1B-, O5L1B-, O5H1B-, O5E1B-, 5W1B-, 5L1B-
Region/Country: Europe, International (IECEx)
Approval Agency: DEKRA
Protection: Ex nAExplosion ProtectionEngleză -
Promag 10, Promag 50, Promag 51, Promag 53, Promag D, Promag L, Promag P, Promag W
Product Code: 5L4B-, 5L4C-, 5L8B-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, O5P1B-, O5P2B-, O5W1B-, 10D-, 10L-, 10P-, 10W-, 50D-, 50L-, 50P-, 50W-, 51P-, 51W-, 53P-, 53W-, 5D4B-, 5D4C-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEngleză -
Promag 10, Promag 50, Promag 51, Promag 53, Promag P
Product Code: 10P-, 50P-, 51P-, 53P-, 5P1B-
Region/Country: France
Approval Agency: ACSHygienic Equipmentfr -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5H1B-, 5P1B-
Region/Country: International
Approval Agency: FieldComm GroupFieldbus ConformanceEngleză -
Promag E, Promag P, Promag H
Product Code: 5H1B-, 5P1B-, 5E1B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFIBUS PA PROFILE 3.0.2Fieldbus ConformanceEngleză -
Promag E, Promag P, Promag H
Product Code: 5E1B-, 5P1B-, 5H1B-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: 1.00.01Fieldbus ConformanceEngleză -
Promag E, Promag H, Promag P
Product Code: 5E1B-, 5H1B-, 5P1B-
Region/Country: International
Approval Agency: ODVAFieldbus ConformanceEngleză -
Promag W, Promag P, Promag L, Promag H, Promag E, Promag D, Promag 55, Promag 53, Promag 51, Promag 50, Promag 10
Product Code: 55S-, 5D4B-, 5D4C-, 5E1B-, 5H1B-, 5H2B-, 5H3B-, 5H5B-, 5L4B-, 5L4C-, 5P1B-, 5P2B-, 5P3B-, 5P5B-, 5W4B-, 5W4C-, 5W5B-, 5W8B-, 55H-, 53W-, 53P-, 53L-, 53H-, 53E-, 51W-, 51P-, 50W-, 50P-, 50L-, 50H-, 50E-, 10W-, 10P-, 10L-, 10H-, 10E-, 10D-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6720MetrologyRusă -
Dosimag OEM, Promag 53, Promag H, Promag P, Promag W
Product Code: 5W5B-, 5W3B-, 5P5B-, 5P3B-, 5P1B-, 5H5B-, 5H3B-, 5H1B-, 5BH-, 53W-, 53P-, 53H-
Region/Country: USA
Approval Agency: NTEP
Approval Number: NTEP 06-019MetrologyEngleză -
Promag D, Promag P, Promag W, Promag H, Promag L, Promag E
Product Code: 5W8B-, 5W4C-, 5L4C-, 5P1B-, 5H1B-, 5H3B-, 5E1B-, 5P2B-, 5D4C-, 5H2B-, 5W4B-, 5L4B-, 5E2B-, 5D4B-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: CH.C.29.004.А NO. 59660/1MetrologyRusă -
Promag H, Promag P
Product Code: 5H1B-, 5P1B-
Region/Country: International
Approval Agency: ABSMarineEngleză -
Promag H, Promag P, Promag W
Product Code: 5H1B-, 5H3B-, 5H5B-, 5P1B-, 5P3B-, 5P5B-, 5W3B-, 5W5B-
Region/Country: International
Approval Agency:MarineEngleză -
Promag P
Product Code: 5P1B-
Region/Country: International
Approval Agency: ABSMarineEngleză -
Promag P
Product Code: 5P1B-
Region/Country: International
Approval Agency: RM RSMarineRusă -
Promag P
Product Code: 5P1B-
Region/Country: International
Approval Agency: DNVGLMarineEngleză -
Promag P
Product Code: 5P1B-
Region/Country: International
Approval Agency: BVMarineEngleză -
Promag P
Product Code: 5P1B-
Region/Country: International
Approval Agency: LRMarineEngleză -
Promag E, Promag H, Promag P
Region/Country:
Heartbeat TechnologyGermană , Engleză
Accesorii / Piese de schimb
-
-
Nr 39 Order code 71185788
Kit T-DAT, 100/300/400/500/500 digital
Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Prosonic Flow/t-mass 300, 500 digital, Promag 400(C). (C) = generation index C.
-
-
-
Nr 30 Order code XPD0010-
-
-
-
Nr 50 Order code XPD0023-
Display module, 4-wire, 100
Usage: Promag 100, Promass 100, Prosonic Flow E 100.
-
-
-
Nr 21 Order code 71185789
Kit cover, compact, Alu
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Consists of: Cover Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.
-
-
-
Nr 20 Order code 71266334
Kit cover, sight glass, compact, Alu
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat. Consists of: Cover with sight glass Aluminium, coated. O-Ring 113,90 x 3,53 NBR for cover.
-
-
-
Nr 70 Order code 71211571
Kit housing gaskets, compact, Alu
Usage: Promag 100. Consists of: O-Ring 113,90 x 3,53 NBR for cover. Gasket EPDM for housing/sensor H. Gasket EPDM for housing/sensor E/P. O-Ring 29,87 x 1,78 HNBR for sensor connector.
-
-
-
Nr 15 Order code 50098036
Kit 10 cable glands M20x1.5 Ex
-
Nr 15 Order code 50098041
Kit 10 ext. M20x1.5/G 1/2" (plug PVC)
-
Nr 15 Order code 50098042
Kit 10 ext. M20x1.5/NPT 1/2" (plug PVC)
-
-
-
Nr 12 Order code 71276494
Kit securing clamp, screw
Usage: Promass 100, Promag 100, Prosonic Flow E 100/E Heat, CNGmass, LPGmass, LNGmass. Sensor housing: Promag 400(C), (C) = generation index C, Promag/Promass 500, Promag/Promass/Prosonic Flow/t-mass 500 digital. Consists of: cover clamp, screw M4x16.
-
-
-
Order code DK5GD-
Promag, grounding disc/protection disc
Includes 1 grounding disc/protection disc
-
Order code DK5GC-
-
Order code XPRFID-
-
-
Predecesor