Specificaţii pe scurt
-
Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.2 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.1 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±0.8 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r. -
Measuring range
Gas: 0.3 m/s to 40 m/s
-
Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell -
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
-
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L), Titan Grade 2
Domeniu de aplicare
For a wide range of gas applications Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. A pressure-rated sensor housing with rupture disc limits safety risks. The compact transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables compliance and process safety at all times.
The measuring principle is unaffected by gas composition
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.
Device properties:
Direct measurement: flow, pressure & temperature
Wetted parts: titanium / 316L
Maximum measuring accuracy: 0.5 %
Compact dual-compartment housing with up to 3 I/Os
Backlit display with touch control and WLAN access
Remote display available
Avantaje
Flexible device with user-definable gas mixtures for demanding measuring tasks
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate
High-performance process control – real-time pressure- and temperature-compensated values
Efficient solution – multivariable, no pressure loss
Full access to process and diagnostic information – numerous, freely combinable I/Os
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Clipuri video
-
Check it out! Scan the code, download the 3D QR app and explore Prosonic Flow G on your own.
-
The Ultrasonic Flow Measuring Principle
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
| Colecții FLEX | Excelenţă tehnică | Simplitate |
|---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
Measuring principle
Ultrasonic flow
-
Product headline
Highly robust gas specialist for fluctuating process conditions with compact, easily accessible transmitter.
Flexible device with user-definable gas mixtures for demanding measuring tasks.
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries. -
Sensor features
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate. High-performance process control – real-time pressure- and temperature-compensated values. Efficient solution – multivariable, no pressure loss.
Direct measurement: flow, pressure & temperature. Wetted parts: titanium / 316L. Maximum measuring accuracy: 0.5 %. -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. -
Nominal diameter range
DN 25 to 300 (1 to 12")
-
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L), Titan Grade 2 -
Measured variables
Volume flow, corrected volume flow, mass flow, flow velocity, speed of sound, pressure, temperature, density, dynamic viscosity, energy flow, Wobbe index, methane fraction, calorific value, molar mass
-
Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.2 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.1 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±0.8 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r. -
Measuring range
Gas: 0.3 m/s to 40 m/s
-
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
-
Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell -
Ambient temperature range
-40 to 60 °C(-40 to +140 °F)
Optional: -50 to 60 °C(-58 to +140 °F) -
Sensor housing material
Stainless Steel, 1.4404(316/316L), 1.4408/1.4409 (CF3M)
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
Polycarbonate -
Degree of protection
Compact version: IP66/67, type 4X enclosure.
Optional: External WLAN antenna: IP67 -
Display/Operation
4-line backlit display with Touch Control (operation from outside)
Configuration via local display and operating tools possible
Remote display available -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, Modbus RS485
-
Power supply
24V DC
100 to 230 V AC
AC 100 to 230 V / DC 24 V (non harzardous area) -
Hazardous area approvals
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex, KC
-
Product safety
CE, C-tick
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a -
Pressure approvals and certificates
PED, CRN
-
Material certificates
3.1 material
NACE MR0175/MR0103
-
-
Informaţii tehnice (TI)
TI Proline Prosonic Flow G 300
-
Informaţii tehnice (TI)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
EN RO 31/01/202416/09/201905/08/2019Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
6 MB
Nume fişier:
TI01385DEN_0324-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Proline Prosonic Flow G 300
-
Instrucţiuni de operare (BA)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
Modbus RS485EN RO 31/01/202416/09/201905/08/2019Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
7.3 MB
Nume fişier:
BA01835DEN_0324-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Proline Prosonic Flow G 300
-
Instrucţiuni de operare (BA)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
HARTEN RO 31/01/202416/09/201905/08/2019Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
8.3 MB
Nume fişier:
BA01834DEN_0324-00.pdf
-
-
-
Parametru dispozitiv (GP)
GP Proline Prosonic Flow G 300
-
Parametru dispozitiv (GP)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
Modbus RS485EN RO 31/01/202405/08/2019Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
2.8 MB
Nume fişier:
GP01131DEN_0224-00.pdf
-
-
-
Parametru dispozitiv (GP)
GP Proline Prosonic Flow G 300
-
Parametru dispozitiv (GP)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
HARTEN RO 31/01/202405/08/2019Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
2.4 MB
Nume fişier:
GP01130DEN_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Proline 300
-
Instrucţiuni scurte (KA)
Versiune în limba română - 01/2024New version available in EnglishTransmiţător HART
cu senzor cu ultrasunete pentru timpul de propagareEN RO 31/01/202405/08/2019Limbă:
Română
Versiune:
31/01/2024
Dimensiune fişier:
2 MB
Nume fişier:
KA01375DRO_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Debitmetru Proline Prosonic Flow G
-
Instrucţiuni scurte (KA)
Versiune în limba română - 01/2024New version available in EnglishSenzor cu ultrasunete pentru timpul de propagare
EN RO 31/01/202405/08/2019Limbă:
Română
Versiune:
31/01/2024
Dimensiune fişier:
960 KB
Nume fişier:
KA01374DRO_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Proline 300
-
Instrucţiuni scurte (KA)
Versiune în limba română - 01/2024New version available in EnglishTransmiţător Modbus RS485
cu senzor cu ultrasunete pentru timpul de propagareEN RO 31/01/202405/08/2019Limbă:
Română
Versiune:
31/01/2024
Dimensiune fişier:
2.1 MB
Nume fişier:
KA01376DRO_0224-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Replacing the electronics
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 09/2025New version available in EnglishProline 300, 500, 500-digital
EN RO 30/09/202501/01/202401/07/202301/06/202131/07/2020Limbă:
Engleză
Versiune:
30/09/2025
Dimensiune fişier:
1.6 MB
Nume fişier:
EA01145DA2_0925-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Alteration with Display and operating module DKX001
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 03/2025New version available in EnglishProline 300
EN RO 15/03/202501/01/202431/07/202002/08/201915/09/2018Limbă:
Engleză
Versiune:
15/03/2025
Dimensiune fişier:
1.3 MB
Nume fişier:
EA01163DA2_0625-00.pdf
-
Alegeţi dintre opţiunile noastre sugerate
-
-- selected coding-- selected label99.999,00<%label%>
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Desene CAD Desene CAD
- Desene CAD
-
Preţuri pe bucată
-
<%range%><%price%>
-
- Accesorii opţionale
Configurare individuală
Frecvent cumpărate împreună
Accesorii
Produse asociate