- F
- L
- E
- X
Ultrasonic clamp-on flowmeter Proline Prosonic Flow P 500 – noninvasive and easy to install – no process interruption – maintenance-free operation up to 550 °C
- F
- L
- E
- X
Award-winning high-temperature clamp-on sensor: Prosonic Flow P 500 has won the AMA Innovation Award 2025
- F
- L
- E
- X
Proline Prosonic Flow P 500 for pipes with line sizes DN 15 to 65 (½ to 2½")
- F
- L
- E
- X
When space is limited: Ultrasonic clamp-on flowmeter with FlowDC function for consistently high performance even at only 2 x DN inlet runs
- F
- L
- E
- X
Flow measurement up to 550 °C (1022 °F) with Prosonic Flow P 500 high temperature sensors
- F
- L
- E
- X
High temperature ultrasonic sensor: robust materials and metal coupling foils for trouble-free and long-term operation
Ultrasonic clamp-on flowmeter Proline Prosonic Flow P 500 – noninvasive and easy to install – no process interruption – maintenance-free operation up to 550 °C
Specificaţii pe scurt
-
Max. measurement error
Volume flow:
±3% o.r. for DN 15
±2% o.r. for DN 25 to DN 200
±2% o.r. above DN 200 -
Measuring range
0 to 15 m/s (0 to 50 ft/s)
-
Medium temperature range
DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F)
DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F)
DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F) -
Max. process pressure
N/A
Domeniu de aplicare
Prosonic Flow P 500 is the ultrasonic clamp-on flowmeter of choice for safe and maintenance-free measurement of conductive and non-conductive liquids, even in challenging applications. It measures flow noninvasively and bidirectionally, independent of pressure, density and conductivity, and without process interruption.
FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
In addition, Prosonic Flow P 500 is available with:
high-temperature sensors for measurement up to 550 °C (1022 °F)
a Petroleum Application Package (PAP), calculating the standard volume for liquid hydrocarbons
Heartbeat Technology, providing continuous process transparency. This way, build-up can be detected before it affects operation
Avantaje
-
Flexible mounting – FlowDC reduces inlet runs to a minimum
-
High safety standards – Prosonic Flow P 500 is developed according to IEC 61508 functional safety requirements and holds international approvals for hazardous area, Zone 1 and Class I, Division 1
-
Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals, also in high-temperature applications (≤550 °C/1022 °F)
-
User-friendly operation – the web server offers full remote access, while the device’s touch display offers convenient on-site interaction
-
Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times
-
Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160")
Clipuri video
-
How to install an Endress+Hauser ultraonic clamp-on flowmeter
-
How FlowDC function reduces inlet runs to a minimum
-
Straightforward application of FlowDC in practice
-
Reliable operation even at high temperatures
-
The ultrasonic flow measuring principle
Colecție Extended
-
Produse superioare
- Extrem de funcțional și convenabil
Excelenţă tehnică
Simplitate
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
| Colecții FLEX | Excelenţă tehnică | Simplitate |
|---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Predecesor
-
Measuring principle
Ultrasonic flow
-
Product headline
Clamp-on flowmeter for limited spaces in process industries with up to 3 I/Os.
Constant accuracy even when mounted with short inlet run thanks to FlowDC.
Bidirectional measurement of various fluids, e.g. liquid hydrocarbons and chemicals. -
Sensor features
High safety standards – SIL by design,
international hazardous area approvals. Long-term stable signal – maintenance-free
permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available.
Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature: –40 to +550 °C (–40 to +1022 °F). -
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety –
freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 3 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. -
Nominal diameter range
Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160")
-
Sensor materials
Clamp on system:
Sensor holder 1.4301/304, 1.4404/316L
Sensor housing 1.4301/304, 1.4404/316L
Strapping bands 1.4301/304, 1.4404/316L -
Measured variables
Volume flow, sound velocity, flow velocity, totalizer
-
Max. measurement error
Volume flow:
±3% o.r. for DN 15
±2% o.r. for DN 25 to DN 200
±2% o.r. above DN 200 -
Measuring range
0 to 15 m/s (0 to 50 ft/s)
-
Max. process pressure
N/A
-
Medium temperature range
DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F)
DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F)
DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F) -
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
–50 to +60 °C (–58 to +140 °F) optional -
Sensor housing material
N/A
-
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L
-
Degree of protection
Sensor remote version: IP68 type 6P
Transmitter remote version: IP66/67, Type 4X enclosure -
Display/Operation
4-line backlit display with touch control(operation from outside)
Optional: WLAN
Configuration via local display and operating tools possible -
Outputs
3 outputs:
4-20 mA HART (active/passive)
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output -
Inputs
Status input
4-20 mA input -
Digital communication
HART, Modbus RS485
-
Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area) -
Hazardous area approvals
ATEX, FM/CSA, EAC, UK Ex, KC
-
Other approvals and certificates
Other approvals and certificates
-
Product safety
CE, C-tick, EAC-marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100
Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
-
-
Informaţii tehnice (TI)
TI Proline Prosonic Flow P 500
-
Informaţii tehnice (TI)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
EN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
7.2 MB
Nume fişier:
TI01504DEN_0224-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Proline Prosonic Flow P 500
-
Instrucţiuni de operare (BA)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
HARTEN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
9.7 MB
Nume fişier:
BA02025DEN_0224-00.pdf
-
-
-
Instrucţiuni de operare (BA)
BA Proline Prosonic Flow P 500
-
Instrucţiuni de operare (BA)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
Modbus RS485EN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
8.9 MB
Nume fişier:
BA02026DEN_0224-00.pdf
-
-
-
Parametru dispozitiv (GP)
GP Proline Prosonic Flow P 500
-
Parametru dispozitiv (GP)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
HARTEN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
2.4 MB
Nume fişier:
GP01147DEN_0224-00.pdf
-
-
-
Parametru dispozitiv (GP)
GP Proline Prosonic Flow P 500
-
Parametru dispozitiv (GP)
Versiune în limba engleză - 01/2024New version available in EnglishUltrasonic time-of-flight flowmeter
Modbus RS485EN RO 31/01/202410/05/2021Limbă:
Engleză
Versiune:
31/01/2024
Dimensiune fişier:
2.9 MB
Nume fişier:
GP01148DEN_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Debitmetru Proline Prosonic Flow P
-
Instrucţiuni scurte (KA)
Versiune în limba română - 01/2024New version available in EnglishSenzor cu ultrasunete pentru timpul de propagare
EN RO 31/01/202410/05/2021Limbă:
Română
Versiune:
31/01/2024
Dimensiune fişier:
1.8 MB
Nume fişier:
KA01474DRO_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Proline 500
-
Instrucţiuni scurte (KA)
Versiune în limba română - 01/2024New version available in EnglishTransmiţător Modbus RS485
cu senzor cu ultrasunete pentru timpul de propagareEN RO 31/01/202410/05/2021Limbă:
Română
Versiune:
31/01/2024
Dimensiune fişier:
2.4 MB
Nume fişier:
KA01476DRO_0224-00.pdf
-
-
-
Instrucţiuni scurte (KA)
KA Proline 500
-
Instrucţiuni scurte (KA)
Versiune în limba română - 01/2024New version available in EnglishTransmiţător HART
cu senzor cu ultrasunete pentru timpul de propagareEN RO 31/01/202410/05/2021Limbă:
Română
Versiune:
31/01/2024
Dimensiune fişier:
2.3 MB
Nume fişier:
KA01475DRO_0224-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
EA Replacing the sensor, sensor holder, Installation set
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 03/2024New version available in EnglishProsonic Flow P 500, I, W 400
EN RO 01/03/202415/12/202101/08/2021Limbă:
Engleză
Versiune:
01/03/2024
Dimensiune fişier:
1.4 MB
Nume fişier:
EA01368DA2_0323-00.pdf
-
-
-
Instrucţiuni de instalare (EA)
Replacing the transmitter
-
Instrucţiuni de instalare (EA)
Versiune în limba engleză - 08/2021New version available in EnglishProsonic Flow 500
EN RO 01/08/2021Limbă:
Engleză
Versiune:
01/08/2021
Dimensiune fişier:
819.1 KB
Nume fişier:
EA01335DA2_0121.pdf
-
Alegeţi dintre opţiunile noastre sugerate
-
-- selected coding-- selected label99.999,00<%label%>
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Desene CAD Desene CAD
- Desene CAD
-
Preţuri pe bucată
-
<%range%><%price%>
-
- Accesorii opţionale
Configurare individuală
Frecvent cumpărate împreună
Accesorii
Produse asociate