Digital nitrate or SAC sensor Viomax CAS51D

Digital nitrate or SAC sensor Viomax CAS51D ©Endress+Hauser
Digital nitrate or SAC sensor Viomax CAS51D ©Endress+Hauser
Digital nitrate or SAC sensor Viomax CAS51D ©Endress+Hauser

Memosens sensor for optical nitrate or SAC measurement in water, wastewater and utilities

Viomax CAS51D is a smart sensor that allows unattended operation in a wide range of process conditions. Just immerse it into your process and measure. The sensor's unique design is extremely robust and it is also low-maintenance thanks to its self-cleaning functionality. With Memosens digital technology, CAS51D combines maximum process and data integrity with simple operation. It enables lab calibration and simplifies predictive maintenance.

Selectare rapidă

Alegeţi dintre opţiunile noastre sugerate
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

sau

Configurare individuală

Selectaţi în continuare dintre toate opţiunile posibile
  • Avantaje

    • Cost-effective: Easy, chemical-free handling is safe, environmentally friendly and saves on operational expenditure.

    • Extremely fast response time: Measured value processing in the sensor provides reliable real-time process information.

    • Fast and easy...

  • Domeniu de aplicare

    Viomax CAS51D measures nitrate or SAC in drinking water, process water and wastewater applications as well as the utilities sector:

    • Organic load or nitrate in inlet and outlet

    • Determination of CODeq or TOCeq

    • Monitoring, control and optimization of...

Caracteristici şi specificaţii

Înapoi

Details

  • Measuring principle

    UV photometric

  • Characteristic

    Insitu (immersion in process), extractive with sample and flow cell
    Optical photometric sensor for nitrate and SAC

  • Size

    388 / 394 mm x 40 mm, depends on version

  • Design

    40 mm sensor, stainless steel 316L

  • Process temperature

    5 to 50°C (41 to 120 °F)

  • Ambient temperature

    -20 to 60 °C (-4 to 140 °F)

  • Specials

    G1, NPT3/4
    IP68 (1m/3,3ft) water column with 1N KCl during 60d ays

  • Application

    Drinking water, biological waste wate process, WWTP effluent
    Monitoring of surface water

  • Measurement range

    0.01 to 20 mg/l / 0.1 to 50 mg/l NO3-N
    0.04 to 80 mg/l / 0.4 to 200 mg/l NO3
    0.1 to 50 1/m / 0.5 to 250 1/m / 1.5 to 700 1/m SAC
    0.15 to 75 mg/l / 0.75 to 370 mg/l / 2.5 to 1000 mg/l COD (254nm)
    0.06 to 30 mg/l / 0.3 to 150 mg/l / 0.9 to 410 mg/l TOC (254nm)

Documente / Manuale / Software

Accesorii / Piese de schimb

Nr
Order code
Specification