Introduceţi cel puţin 2 caractere pentru a începe căutarea.

TH15
Modular RTD thermometer, US style

TH15
Modular RTD thermometer, US style ©Endress+Hauser

Best in class temperature measurement for general applications

The robust device is a unit ready for use within and existing thermowell and includes various housing transmitter heads to meet the application and space requirement needs. The unit offers enhanced measurement accuracy and reliability. A variety of connections, dimensions and materials (like 316L SS and Hastelloy C276) offer flexible application possibilities.

  • Produse simple

  • Ușor de ales, instalat și administrat

Excelenţă tehnică

Simplitate

  • Produse clasice

  • Fiabile, robuste și ușor de întreținut

Excelenţă tehnică

Simplitate

  • Produse superioare

  • Extrem de funcțional și convenabil

Excelenţă tehnică

Simplitate

  • Produse de specialitate

  • Conceput pentru aplicatii solicitante

Excelenţă tehnică

Simplitate

Variabil

Colecții FLEX Excelenţă tehnică Simplitate
  • F
  • L
  • E
  • X

Colecție Fundamental

Îndepliniți-vă nevoile esențiale de măsurare

Excelenţă tehnică
Simplitate
  • F
  • L
  • E
  • X

Selecţie Lean

Gestionați-vă cu ușurință procesele de bază

Excelenţă tehnică
Simplitate
  • F
  • L
  • E
  • X

Colecție Extended

Optimizați-vă procesele cu tehnologii inovatoare

Excelenţă tehnică
Simplitate
  • F
  • L
  • E
  • X

Colecție Xpert

Stăpâniţi cele mai dificile aplicaţii

Excelenţă tehnică
Simplitate

Variabil

  • Specificaţii pe scurt

    • Accuracy

      class A acc. to IEC 60751
      class B acc. to IEC 60751

    • Max. process pressure (static)

      class AA acc. to IEC 60751
      class A acc. to IEC 60751
      class B acc. to IEC 60751

    • Operating temperature range

      PT100 WW:
      -200 °C … 600 °C
      (-328 °F … 1.112 °F)
      StrongSens:
      -50 °C … 500 °C
      (-58 °F … 932 °F)
      PT100 TF:
      -50 °C … 200 °C
      (-58 °F … 392 °F)

    • Max. immersion length on request

      up to 41" (1041 mm)
      others on request

Selectare rapidă

Alegeţi dintre opţiunile noastre sugerate
Preţ de vânzare
  • <%label%>
  • <%feature%>
      <%label%>
      99.999,00
    • Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
  • Process Connection
  • <%message%>

sau

Configurare individuală

Selectaţi în continuare dintre toate opţiunile posibile
  • Avantaje

    • High flexibility due to modular assembly with standard terminal heads and customized immersion length

    • One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry...

  • Domeniu de aplicare

    The TH15 temperature sensors are RTD assemblies designed for use in all types of process industries, including harsh environments, due to their rugged design.
    They are made up of a measurement probe with an insulated RTD element and sheath.

    The sensor...

Caracteristici şi specificaţii

Înapoi

Details

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    Industrial US style

    modular temperature assembly

    with extension

    to be used with existing thermowell

  • Thermowell / protection tube

    to be used with thermowell

  • Insert / probe

    mineral insulated (MI), flexible

    PTFE-insulated, rigid

  • Outer diameter protection tube / Insert

    Insert 1/4'' (6,35 mm)

  • Max. immersion length on request

    up to 41" (1041 mm)

    others on request

  • Material protection tube/ thermowell

    Sensor sheath

    316/316L

  • Optional coating

    Not applicable

  • Process connection

    Schutzrohranschluss

    Außen-Gewinde:

    NPT1/2"
    1-1/4"-18 UNEF

  • Tip shape

    straight

  • Surface roughness Ra

    Not defined

  • Operating temperature range

    PT100 WW:

    -200 °C … 600 °C

    (-328 °F … 1.112 °F)

    StrongSens:

    -50 °C … 500 °C

    (-58 °F … 932 °F)

    PT100 TF:

    -50 °C … 200 °C
    (-58 °F … 392 °F)

  • Max. process pressure (static)

    class AA acc. to IEC 60751

    class A acc. to IEC 60751

    class B acc. to IEC 60751

  • Accuracy

    class A acc. to IEC 60751

    class B acc. to IEC 60751

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    transmitter only

    FM IS

    CSA IS

    FM/CSA IS

  • Certification

    SIL (transmitter only)

Documente / Manuale / Software

Accesorii / Piese de schimb

Nr
Order code
Specification
  • F
  • A
    • Nr A Order code TS212-

      iTHERM Insert imperial TS212

      Insert replaceable central spring load imperial version ::Fastest response times for optimal process control through iTHERM QuickSens insert. ::Maximum robustness for highest process safety through iTHERM StrongSens insert. Maximum RTD accuracy at high temperature through iTHERM HotSens insert.

    • Nr A Order code TU111-

      RTD Insert TU111, General Purp, US Style

      Spare part. Spring loaded. General purpose. Pt100 Sensor comply with IEC60751 standard, alpha=0.00385.

  • F
  • F
    • Nr F Order code TA30H-

      Terminal Head TA30H

      Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50 150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).

  • A
    • Nr A Order code TA30R-

      Terminal Head TA30R

      Retainer for terminal block or head transmitter + optional display. Cover: screwed, optional window. Material: Stainless Steel 316L. Colour: Steel (no coating). Ambient Temp.: -50...85/130 oC (display/standard). Protection: IP66/68, NEMA4X; IP69K (housing). :: easy wiring through best accessibility. :: compact desing and low weight.

  • F
    • Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Product being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Product being phased out, limited availability. Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Order code TMT71-

      iTEMP TMT71, Transmitter 4-20mA

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.

    • Order code TMT72-

      iTEMP TMT72, Transmitter HART

      2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.

    • Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

    • Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code TXU10-

      Configuration Kit TXU10

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code READWIN-

      Readwin 2000 Operation + Read. software

    • Order code TID10-

      Display Unit Head Transmitter

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82, TMT71, TMT72.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code TMT142E-

      Electronic TMT142E

  • F