T55
Explosion proof TC thermometer, US style
Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry
The high modular thermometer is used for several applications with harsh environments, e.g. in Power Plants, Refineries or in the Chemical or Petrochemical industry. The robust device is designed for use within an existing thermowell. With different head transmitter it's a complete unit ready for use with enhanced measurement accuracy and reliability.
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
Specificaţii pe scurt
-
Accuracy
Standard acc. to ASTM E-230
Special acc. to ASTM E-230 -
Response time
63% rt = 1 s
-
Max. process pressure (static)
not applicable
-
Operating temperature range
Type T:
-270 °C ...370 °C
(-454 °F ...698 °F)
Type J:
-210 °C ...720 °C
(-346 °F ...1.328 °F)
Type E:
-270 °C ...820 °C
(-454 °F ...1.508 °F)
Type K:
-270 °C ...1.150 °C
(-454 °F ...2.102 °F)
Type N:
-270 °C ...1.150 °C
(-454 °F ...2.102 °F) -
Max. immersion length on request
up to 100" (2540 mm)
others on request
-
Selectare rapidă
Configurare individuală
-
Avantaje
FM/CSA XP Class I, Div. 1 approved temperature assemblies for maximum safety
One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications
Remove and install...
-
Domeniu de aplicare
The sensor assembly can be used in process industries such as:
Chemicals
Petrochemical
Refineries
Offshore Platforms
Documente / Manuale / Software
-
T53, T54 and T55
Thermocouple assemblies T53, T54 and T55 for heavy duty applications
Technical Information (TI) -
KA245R T55 explosion proof thermocoupld assembly
T55 Explosion proof thermocouple assembly
Short Instruction (KA)05/07Engleză -
Temperature assemblies T13, T14, T15, T53, T54, T55
Control drawing CSA (XP, DIP)
Installation notes for CSA approved apparatus
Ex Safety Instructions (XA) -
Temperature assemblies T15, T55
Measurement inserts TU211, TU221
Installation notes for CSA explosion proof approved apparatus XP, DIP,
NI
Temperature Process RTD Explosion Proof T15, Process TC Explosion
Proof T55, RTD insert TU211, TC insert TU221 Installation NotCertificate FM/CSA (ZD) -
Control Drawing FM Explosionproof T15, T55, TU211, TU221
Temperature Process RTD Explosion Proof T15, Process TC Explosion Proof
T55, RTD insert TU211, TC insert TU221
Installation Notesfor Hazardous LocationsCertificate FM/CSA (ZD) -
Control Drawing FM XP, NI, DIP
T15, T55, TU211, TU221
Temperature Process RTD Explosion Proof T15, Process TC Explosion
Proof
T55, RTD insert TU211, TC insert TU221
Installation Notesfor Hazardous LocationsCertificate FM/CSA (ZD) -
Temperature assemblies T15, T55
Measurement inserts TU221, TU211
Installation notes for CSA explosion proof approved apparatus
Temperature Process RTD Explosion Proof T15, Process TC Explosion
Proof T55, RTD insert TU211, TC insert TU221 Installation NotCertificate FM/CSA (ZD) -
Temperature assemblies T15, T55
Temperature inserts TU221, TU211
Control drawing FM (XP, DIP)
Installation Notes for FM approved apparatus
Certificate FM/CSA (ZD) -
Control Drawing CSA Intrinsically Safety, Nonincendive THxx, Txx Series,
TU111, TU121, TU211, TU221
Installation Notes for Hazardous Locations
Certificate FM/CSA (ZD) -
Измерение температуры
Ключевые особенности термометров Endress+Hauser для нефтегазовой отрасли
Competence Brochure (CP)08/11Rusă -
Инженерные решения по термометрии
Специальные решения по термометрии для химической и
нефтеперерабатывающей промышленностиCompetence Brochure (CP)04/10Rusă -
RTD-thermometer, Process TC Heavy duty, Process TC General purpose, Process TC Explosion proof, Process TC direct in contact, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Explosion proof, Process RTD direct in contact, Process RTD Direct contact, Plugs RTD direct contact, Magphant, Low cost RTD General purpose, Industrial Modular Thermometer
Product Code: TR15-, TR13-, TR12-, TR11-, TR10-, TMT470L-, TMT162R-, TMT162C-, TMT142R-, TMT142C-, TMR35L-, TMR35-, TMR31L-, TMR31-, TM411-, TM401-, TH56-, TH55-, TH54-, TH53-, TH52-, TH51-, TR24-, TTR35-, TTR31-, TST90-, TST602-, TST487-, TST434-, TST41N-, TST414-, TST410-, TST40N-, TST310-, TST187-, TSM487-, TSM187-, TSC310-, TR88-, TR66-, TR65-, TR63-, TR62-, TR61-, TR25-, TH27-, T55-, T54-, T53-, T15-, T14-, T13-, OTR96-, OTR95-, OTR94-, OTR93-, OTR92-, OTR91-, OTR90-, OTR35-, OTR31-, MLTTS01-, MLTTS00-, GPTL-, DTT35L-, DTT35-, DTT31L-, DTT31-, TAF11-, TH18-, TH17-, TH15-, TH14-, TH13-, TH12-, TH11-, TEC420-, TC88-, TC66-, TC65-, TC63-, TC62-, TC61-, TC15-, TC13-, TC12-, TC10-, TAF16-, TAF12T-, TAF12S-, TAF12D-
Declaration Number: EC_00568_01.17EU DeclarationGermană , Engleză , fr -
ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, Process RTD Explosion proof, Process RTD General purpose, Process TC Explosion proof
Product Code: T13-, T14-, T15-, T53-, T54-, T55-, TM111-, TM131-, TU211-, TU221-
Region/Country: USA, Canada
Approval Agency: CSA
Category: II,III/1/E,F,G/TXXX°C, I/1/1/T6...T1, I/1/A,B,C,D/T6...T1, I/2/A,B,C,D/T6...T1
Protection: XP, NI, DIPExplosion ProtectionEngleză -
ACCESSORIES: RTD INSERT, ACCESSORIES: TC INSERT, Process RTD Explosion proof, Process TC Explosion proof
Product Code: T13-, T14-, T15-, T53-, T54-, T55-, TU211-, TU221-
Region/Country: USA
Approval Agency: FM
Category: I,II,III/1,2/A,B,C,D,E,F,G/
Protection: DIP, XPExplosion ProtectionEngleză -
Process RTD Explosion proof, Process RTD General purpose, Process RTD Hygienic, Process TC Explosion proof
Product Code: T13-, T14-, T15-, T53-, T54-, T55-, TM111-, TM131-, TM411-, TM412-
Region/Country: USA, Canada
Approval Agency: CSAOrdinary Location Product SafetyEngleză
Accesorii / Piese de schimb
-
-
Order code 71310423
-
Order code 51004948
-
Order code TMT142X-DA
Display HART5 + fitting kit + twist protection
-
Order code TMT142X-DC
Display fitting kit + twist protection
-
-
-
Nr B Order code TMT142X-HA
Housing cover blind, 316L Ex d, FM XP, CSA XP + O-ring
-
Nr B Order code TMT142X-HC
Housing cover cpl. for display,316L Ex d FM XP, CSA XP, with O-ring
-
Nr B Order code TMT142X-HH
Housing cover blind, Alu Ex d FM XP without O-ring CSA XP only as cover of terminal part
-
Nr B Order code TMT142X-HK
Housing cover cpl. for display, Alu Ex d + O-ring
-
Nr B Order code TMT162X-HA
Housing cover blind, 316L Exd ATEX Ex d, FM XP + O-ring CSA XP only as cover of terminal part
-
Nr B Order code TMT162X-HC
Housing cover cpl. for display,Ex d,316L ATEX Ex d, FM XP, CSA XP + O-ring
-
Nr B Order code TMT162X-HH
Housing cover blind, Alu Ex d FM XP + O-ring CSA XP only as cover of terminal part
-
Nr B Order code TMT162X-HK
Housing cover cpl. for display,Alu Ex d + O-ring
-
-
-
Order code 51006845
Cable gland NPT1/2, D4.5-8.5 IP68
-
Order code 51007995
Mounting bracket SS316L, tube 1,5-3"
-
Order code 71044062
Fixing kit cpl. TMT8x/7x USA(american)
2x screws, 1x sealing CDI-connector
-
Order code TMT162X-DA
Display HART5 + fitting kit + twist protection
-
Order code TMT162X-DB
Display PA/FF + fitting kit + twist protection
-
Order code TMT162X-DC
Display fitting kit + twist protection
-
Order code TMT162X-DD
Display HART7 + fitting kit + twist protection
-
Order code TMT162A-MA
Mounting bracket,North American region standard model,stainl.steel wall/tube 2"
-
Order code TMT162A-MB
Cable gland NPT1/2, North American region standard model,2xD0.5 cables
-
Order code TMT162A-MD
Mounting bracket 2"tube V4A
-
Order code 71386275
Integrable Surge Arrester Module
for subsequent mounting in field transmitter. Ensure compatibility.
-
-
-
Nr A Order code TU221-
TC-Insert TU221, Approved, U.S.Style
Spare part. Thermocouple Insert spring loaded. Flame path Nipple. Thermocouple comply with EMF tables of ASTM E-230 and IEC60584, color codes per ASTM E-230
-
-
-
Nr B Order code TU401-
Enclosure TU401, U.S.Style
-
Nr B Order code TA30H-
Terminal Head TA30H
Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50 150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).
-
-
-
Order code TMT142E-
Electronic TMT142E
-
Order code TMT162E-
Electronic TMT162
-
Order code TMT182-
iTEMP TMT182, Head Transmitter HART
Product being phased out, limited availability. Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Order code TMT71-
iTEMP TMT71, Transmitter 4-20mA
2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
-
Order code TMT72-
iTEMP TMT72, Transmitter HART
2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
-
Order code TMT82-
iTEMP TMT82, Transmitter HART
2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.
-
Order code TMT84-
iTEMP TMT84, Transmitter PA
Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
Order code TMT85-
iTEMP TMT85, Transmitter FF
Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.
-
Order code TID10-
Display Unit Head Transmitter
to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.
-
Order code TXU10-
Configuration Kit TXU10
for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.
-
Order code FXA195-
Commubox FXA195
Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.
-
Order code READWIN-
Readwin 2000 Operation + Read. software
-
Order code TMT181-
iTEMP TMT181, Head Transmitter PCP
Product being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-