Specificaţii pe scurt
-
Measured variables
Volumetric flow, a. c., volume a. c., gas velocity, sound velocity
-
Measuring Medium
Natural gas, air, C2H4, steam, process gases (e. g. CO2 up to 100%, N2, O2, Cl2 etc.), gases like sour gas or bio gas with high H2S content
-
Nominal pipe size
2" ... 24"
(DN 50 ... DN 600)
Domeniu de aplicare
The FLOWSIC600 is an ultrasonic flowmeter that sets the standard in its market segment. The design shows that it is geared towards the harsh conditions of the industry. Thanks to its compact design with integrated cable routing, the measuring system is durable, fail-safe, low-maintenance, and exhibits long-term stability. The FLOWSIC600 has extensive diagnostic options that allow faults to be detected before the measurement is affected and offers process monitoring based on the speed of sound.
Process gases flow metering
Industry gas metering CO2, H2, Air, N2, O2, NH3, Ethylene, Helium, Argon
Internal allocation measurement
For gases with high H2S component such as sour gas or biogas
Device properties:
Highly efficient ultrasonic transducer - up to gas temperatures of +105 °C and pressures up to 250 bar
Direct path layout
Intelligent self-diagnostics
Compact, robust design
Integrated log book and data logger
Large measuring range 1:120
Bidirectional measurement
Low power consumption: <1 W
Avantaje
Long-term stability, reliable measurement
Low maintenance due to intelligent self-diagnostics
Virtually immune to pressure regulator noise
Ultrasonic transducers can be exchanged under operating pressure
Wide application range
Colecție Xpert
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil

-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
Measuring principle
Ultrasonic transit time difference measurement
-
Measured variables
Volumetric flow, a. c., volume a. c., gas velocity, sound velocity
-
Measuring Medium
Natural gas, air, C2H4, steam, process gases (e. g. CO2 up to 100%, N2, O2, Cl2 etc.), gases like sour gas or bio gas with high H2S content
-
Repeatability
< 0.1 % of the measured value
-
Accuracy
2-path version ≤ ± 1 %
4-path version ≤ ± 0.5 %
Typical accuracy, see application specific data for detailed information -
Medium temperature range
ATEX:
–40 °C ... +105 °C at T1, T2, T3;
–40 °C ... +91 °C at T4
Other Ex certifications: –40 °C ... +180 °C -
Operating pressure range
0 bar (g) ... 250 bar (g)
On request: Up to 450 bar (g) -
Nominal pipe size
2" ... 24"
(DN 50 ... DN 600) -
Metrological approvals and certificates
ISO 17089-2
MTBF: 15.4 years -
Hazardous area approvals
IECEx:
Gb/Ga Ex db eb ib [ia Ga] IIA T4
Gb/Ga Ex db eb ib [ia Ga] IIC T4
Ultrasonic transducers intrinsically safe
ATEX:
II 1/2 (1) G Ex ia/db eb ia [ia Ga] IIA/IIB/IIC T4...T1 Ga/Gb
III 1/2 (1) G Ex ia/db eb ia [ia Ga] IIC T6 Ga/Gb
Ultrasonic transducers intrinsically safe
NEC/CEC (US/CA):
Class I, Division 1, Groups B, C, D T4
Class I, Division 2, Groups A, B, C, D T4
Class I, Division 1, Group D T4
Class I, Division 2, Group D T4
Ultrasonic transducers intrinsically safe -
Digital Outputs
3 outputs:
30 V, 10 mA
Passive, electrically isolated, Open Collector or according to NAMUR (EN 50227), fmax = 6 kHz
(scalable) -
Digital communication
Modbus ASCII
Modbus RTU
HART
-
-
Broşură de competenţă (CP)
FLOWSIC – flow meters and instruments
-
Broşură de competenţă (CP)
Versiune în limba engleză - 05/2025Precise quantity measurement for accurate billing and process control
Limbă:
Engleză
Versiune:
13/05/2025
Dimensiune fişier:
3.1 MB
Nume fişier:
8030079_CP_Flow_meters_en_V2-0_2025.05_EHS_WEB.pdf
-
-
-
Broşură de competenţă (CP)
MISURATORI E STRUMENTI PER LA PORTATA FLOWSIC
-
Broşură de competenţă (CP)
Versiune în limba italiană - 05/2025MISURATORI E STRUMENTI PER
LA PORTATA FLOWSIC
Misura precisa delle quantità –
fatturazione precisa e controllo di
processoLimbă:
Italiană
Versiune:
27/05/2025
Dimensiune fişier:
6.1 MB
Nume fişier:
CP01584D16IT_02.25-00.pdf
-
-
-
Inovaţie (IN)
FLOWSIC600 – reliable flowmeter for process applications
-
Inovaţie (IN)
Versiune în limba engleză - 01/2025The FLOWSIC600 measurement device is an ultrasonic gas flowmeter and sets the standard in its market segment.
Limbă:
Engleză
Versiune:
01/01/2025
Dimensiune fişier:
3.3 MB
Nume fişier:
8029730_IN_FLOWSIC600_en_V5-0_2025.01_EHS.pdf
-
-
-
Software aplicaţie
FLOWgate
-
Software aplicaţie
Versiune - 1.30.0Software for configuration and parameterization of FLOWSIC ultrasonic flowmeter
Limbă:
Language neutral
Versiune:
11/11/2024
Dimensiune fişier:
430 MB
Nume fişier:
FLOWgate
-
Alegeţi dintre opţiunile noastre sugerate
-
-- selected coding-- selected label99.999,00<%label%>
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Căutaţi mai multe opţiuni? Utilizaţi un configurator individual pentru a continua.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- Desene CAD Desene CAD
- Desene CAD
-
Preţuri pe bucată
-
<%range%><%price%>
-
- Accesorii opţionale