Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
Raman Rxn-10
Raman bio sleeve
The bio multi optic is a critical part for easy, reliable, real-time bioprocess measurements with maximum sterility and efficiency. The non-contact multi optic features a patented self-aligning lens for top spectral quality and reproducibility. It pairs with the Rxn-10 probe and connects to an autoclavable (or gamma sterilizable), disposable bio sleeve via an easy snap-in-place design. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactors.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Improved ease of use and reduced maintenance for bioprocessing
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
Optimized spectral performance when used with a compatible bio sleeve
Produse superioare
Excelenţă tehnică
Simplitate
Produse de specialitate
Excelenţă tehnică
Simplitate
Variabil
| Colecții FLEX | Excelenţă tehnică | Simplitate |
|---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
System design and specifications for Rxn-10 probe optics: Raman
immersion optics (KIO1), non-contact optics (KNCO1),
bIO-Optics (KLBIO1), bio multi optics (KRBMO), bio sleeves
(KRBSL), and Raman optic system for single use (KRSU1)
| EN | RO | ||
|
09/07/2026
|
|
|
|
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
09/07/2026 |
|
Dimensiune fişier: |
504.3 KB |
|
Nume fişier: |
TI01635CEN_0426.pdf |
System design and specifications for the multi optic calibration
and verification kit
| EN | RO | ||
|
26/06/2023
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
26/06/2023 |
|
Dimensiune fişier: |
478.7 KB |
|
Nume fişier: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications for the Raman Rxn-10 probe
| EN | RO | ||
|
08/09/2025
|
|
|
|
|
13/11/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
08/09/2025 |
|
Dimensiune fişier: |
949 KB |
|
Nume fişier: |
TI01629CEN_0525.pdf |
Commissioning, operation, and maintenance details for Rxn-10
probe optics: Raman immersion optics (KIO1), non-contact
optics (KNCO1), bIO-Optics (KLBIO1), bio multi optic
(KRBMO), bio sleeve (KRBSL), and Raman optic system for
single use (KRSU1)
| EN | RO | ||
|
08/06/2026
|
|
|
|
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
08/06/2026 |
|
Dimensiune fişier: |
2.9 MB |
|
Nume fişier: |
BA02171CEN_0426.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
| EN | RO | ||
|
08/09/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
08/09/2025 |
|
Dimensiune fişier: |
1.8 MB |
|
Nume fişier: |
BA02160CEN_0525.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
| EN | RO | ||
|
26/06/2023
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
26/06/2023 |
|
Dimensiune fişier: |
996.4 KB |
|
Nume fişier: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Quick start guide for the Raman Rxn-10 probe
| EN | RO | ||
|
02/12/2024
|
|
|
|
|
31/05/2023
|
|
|
|
|
13/09/2022
|
|
|
|
|
08/09/2021
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
02/12/2024 |
|
Dimensiune fişier: |
1.6 MB |
|
Nume fişier: |
KA01546CEN_0424.pdf |
Quick start guide for Rxn-10 probe optics: Raman immersion optics
(KIO1), non-contact optics (KNCO1), bIO-Optics (KLBIO1), bio
multi optics (KRBMO), bio sleeves (KRBSL), and
Raman optic system for single use (KRSU1)
| EN | RO | ||
|
08/06/2026
|
|
|
|
|
31/05/2023
|
|
|
|
|
03/08/2022
|
|
|
|
Limbă: |
Engleză |
|
Versiune: |
08/06/2026 |
|
Dimensiune fişier: |
1.1 MB |
|
Nume fişier: |
KA01551CEN_0426.pdf |
This self-assessment questionnaire helps pharmaceutical and API
manufacturers evaluate their readiness for implementing online
Raman spectroscopy. A simple scoring system identifies potential
infrastructure, integration, and process monitoring challenges, helping
teams assess deployment complexity and prepare for successful
real-time analytical monitoring.
|
Limbă: |
Engleză |
|
Versiune: |
24/08/2026 |
|
Dimensiune fişier: |
111.2 KB |
|
Nume fişier: |
PU01649CEN_0126.pdf |
This self-assessment questionnaire helps bioprocessing teams evaluate
analytical costs and delays associated with scaling up from laboratory
development to production. A scoring system helps identify optimization
opportunities and assess the value of real-time monitoring using online
Raman spectroscopy.
|
Limbă: |
Engleză |
|
Versiune: |
24/08/2026 |
|
Dimensiune fişier: |
111.4 KB |
|
Nume fişier: |
PU01647CEN_0126.pdf |