Introduceţi cel puţin 2 caractere pentru a începe căutarea.

Assembly for process photometers
OUA260

Flow assembly for process photometers ©Endress+Hauser

Flow assembly for a variety of optical inline measurements

OUA260 is the best-in-class flow assembly for absorption, color and turbidity measurements. Its ultra-hygienic design and certified biocompatibility meet the highest demands to protect your products reliably from contamination. Multiple process connections and available materials ensure a perfect fit and performance even in aggressive media. Better still, its low cell volume speeds up sensor response times, thus providing you with fast measuring values.

  • Produse simple

  • Ușor de ales, instalat și administrat

Excelenţă tehnică

Simplitate

  • Produse clasice

  • Fiabile, robuste și ușor de întreținut

Excelenţă tehnică

Simplitate

  • Produse superioare

  • Extrem de funcțional și convenabil

Excelenţă tehnică

Simplitate

  • Produse de specialitate

  • Conceput pentru aplicatii solicitante

Excelenţă tehnică

Simplitate

Variabil

Colecții FLEX Excelenţă tehnică Simplitate
  • F
  • L
  • E
  • X

Colecție Fundamental

Îndepliniți-vă nevoile esențiale de măsurare

Excelenţă tehnică
Simplitate
  • F
  • L
  • E
  • X

Selecţie Lean

Gestionați-vă cu ușurință procesele de bază

Excelenţă tehnică
Simplitate
  • F
  • L
  • E
  • X

Colecție Extended

Optimizați-vă procesele cu tehnologii inovatoare

Excelenţă tehnică
Simplitate
  • F
  • L
  • E
  • X

Colecție Xpert

Stăpâniţi cele mai dificile aplicaţii

Excelenţă tehnică
Simplitate

Variabil

  • Specificaţii pe scurt

    • Process temperature

      0-130 °C (32-194 °F)

    • Process pressure

      up to 100 bar (1450 psi) depending on material, mean diameter and process connection

Selectare rapidă

Alegeţi dintre opţiunile noastre sugerate
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

sau

Configurare individuală

Selectaţi în continuare dintre toate opţiunile posibile
  • Avantaje

    • Fast measuring values thanks to low cell volume

    • Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)

    • Certified biocompatibility according to USP class VI

    • Ultra-hygienic thanks to electropolished surface Ra=0.4 µm (16 µinch)

    • Extremely...

  • Domeniu de aplicare

    The OUA260 flow cell is used in combination with:

    • OUSAF12 Suspended solids and color sensor

    • OUSAF22 Color sensor

    • OUSAF44 UV absorption sensor

    • OUSTF10 Turbidity and suspended solids sensor

    Typical applications are:

    • Chromatography control

    • Filtration...

Caracteristici şi specificaţii

Înapoi

Details

  • Measuring principle

    UV absorbance

  • Application

    Flow assembly for use in combination with photometric sensors OUSAFxx and OUSTF10

  • Material

    Body: SS316L, Kynar, further on request
    Windows: Pyrex, Quartz or Sapphire
    O-rings: Viton, Silicone, EPDM, Kalrez

  • Process temperature

    0-130 °C (32-194 °F)

  • Process pressure

    up to 100 bar (1450 psi) depending on material, mean diameter and process connection

Documente / Manuale / Software

Accesorii / Piese de schimb

Nr
Order code
Specification