Vibronic
Point level detection
Nivotester FailSafe FTL825
Point level switching unit for Liquiphant FailSafe FTL80, FTL81 and FTL85
The Nivotester FTL825 supplies the Liquiphant FailSafe FTL8x point level switch with direct voltage via a two-wire cable. At the same time, it analyzes the current values (4-20mA discrete) of the Liquiphant and returns a switching signal. The signal inputs of the Nivotester FTL825 are galvanically isolated from the mains and the output and can be ordered Safety-critical systems up to SIL3. For industries where redundant or diverse systems are either not recommended or not possible.
- F
- L
- E
- X
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
Selectare rapidă
Configurare individuală
-
Avantaje
Use in safety systems requiring functional safety to SIL3 in accordance with
IEC 61508 Ed.2.0 /IEC 61511-1 / ISA 84-1Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button
For safety-critical systems up to SIL3...
-
Domeniu de aplicare
FailSafe point level switch unit for top hat rail mounting.
Ambient temperature: -20 to +60°C (-4 to +140°F)
International explosion protection certificates, overfill prevention WHG
Documente / Manuale / Software
-
Nivotester FailSafe FTL825
Technical Information
Point level switch
For Liquiphant FailSafe FTL80, FTL81 and
FTL85Technical Information (TI) -
Nivotester FailSafe FTL825
Operating Instructions
Point level switch
For Liquiphant FailSafe FTL80, FTL81 and
FTL85Operating Instruction (BA) -
Fuse on Nivotester FTL825
Installation instruction
Nivotester FTL825
Installation Instructions (EA) -
Nivotester FailSafe FTL825
Control Drawing AIS + ANI
Ex Safety Instructions (XA) -
Nivotester FailSafe FTL825
Installation Drawing AIS + ANI
Ex Safety Instructions (XA) -
Nivotester FailSafe FTL825
[Ex ia Ga] IIC
[Ex iaD]Ex Safety Instructions (XA) -
Nivotester FailSafe FTL825
[Ex ia Ga] IIC X
[Ex ia Da] IIIC XEx Safety Instructions (XA) -
Nivotester FailSafe FTL825
ATEX:
II (1) G [Ex ia Ga] IIC
II (1) D [Ex ia Da] IIIC
IECEx:
[Ex ia Ga] IIC
[Ex ia Da] IIICEx Safety Instructions (XA) -
Liquiphant FailSafe FTL80, FTL81, FTL85
Allgemeine bauaufsichtliche Zulassung Z-65.11-507 (DIBt)
Standgrenzschalter (Schwingsonde) mit Messumformer als Teil
von ÜberfüllsicherungenCertificate (ZE) -
Liquiphant FailSafe FTL80, FTL81, FTL85
Allgemeine bauaufsichtliche Zulassung Z-65.40-508 (DIBt)
Leckagesonde (Schwingsonde) mit Messumformer als Anlageteil
von LeckageerkennungssystemenCertificate (ZE) -
Functional Safety Manual (SIL)
Liquiphant FailSafe FTL80, FTL81, FTL85
Nivotester FailSafe FTL825
Operating minimum (e.g. dry run protection) and maximum monitoring (e.g.
overfill protection) of all types of liquids in vessels to satisfy
particular safety systems requirements as per IEC 61508 Edition 2.0Special Documentation (SD) -
Liquiphant FailSafe FTL80, FTL81, FTL85,
Nivotester FailSafe FTL825
Functional Safety data sheet (SIL) /
Datenblatt zur Funktionalen Sicherheit (SIL)Special Documentation (SD) -
kurier 02-2013
Kundenmagazin: Einheitlich und einfach clever
Customer Magazine (CM)07/13Germană -
Liquiphant FailSafe
Detección de nivel para el máximo grado de seguridad
Innovations (IN)06/12Spaniolă -
Liquiphant FailSafe
Der Grenzstandschalter für ein Höchstmaß an Sicherheit
Innovations (IN)03/13Germană -
Liquiphant FailSafe
Point level switch for the maximum degree of safety
Innovations (IN)03/13Engleză -
Liquiphant FailSafe
American version: Point level switch for the maximum degree of safety
Innovations (IN)01/13Engleză -
Nivotester FailSafe
Product Code: FTL825-
Declaration Number: HE_01046_01.18
Manufacturer Specification: LPG / LNG / CNGManufacturer DeclarationGermană , Engleză -
Nivotester FailSafe
Product Code: FTL825-
Declaration Number: EC_00099_03.15EU DeclarationGermană , Engleză , fr -
Liquiphant, Nivotester
Product Code: FTL825-
EU DeclarationGermană , Engleză , fr -
SYSTEM, Pumpenschutz, Nivotester FailSafe, Nivotester, Micropilot S, Micropilot, Liquipoint T, Liquiphant T, Liquiphant S, Liquiphant M, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Levelflex
Product Code: FTL260-, FMP52-, FMP54-, FMR52-, FMR54-, FMP55-, FMP53-, FMR51-, FMP51-, FMR53-, FMR62-, FTL51-, FMR50-, FTL51H-, FTL50H-, FMP50-, NMR84-, FTL51C-, FMR60-, FTL71-, FTL70-, FTL31-, FTL325N-, FTL325P-, FTL33-, FTL375P-, FTL50-, FTL80-, FTL825-, FTL85-, FTW31-, FTL81-, FTW32-, FTW325-, FTW360-, NMR81-, FTI52-, FMI21-, FMI51-, FMI52-, FMR10-, FMR20-, FMR530-, FMR532-, FMR533-, FMR540-, FTC325-, FTI51-
Region/Country: Russia (Declaration of Conformity), Russia (TR CU)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05528MiscellaneousRusă -
SYSTEM, Pumpenschutz, Nivotester FailSafe, Nivotester, Micropilot S, Micropilot, Liquipoint T, Liquipoint, Liquiphant T, Liquiphant S, Liquiphant M, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Levelflex, Einstabsonde, Dreistabsonde, Doppelstabsonde
Product Code: FTL70-, FTL51H-, FTL51C-, FTL51-, FTL50H-, FTL50-, FTL375P-, FTL33-, FTL325P-, FTL325N-, FTL31-, FTL260-, FTI52-, FTI51-, FTL71-, FTL80-, FTL81-, FTL825-, FTL85-, FTW23-, FTW31-, FTW32-, FTW325-, FTW33-, FTW360-, NMR81-, NMR84-, 11362Z-, 11363Z-, 11371-, 11375Z-, 11961Z-, FMI21-, FMI51-, FMI52-, FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMR10-, FMR20-, FMR50-, FMR51-, FMR52-, FMR53-, FMR530-, FMR532-, FMR533-, FMR54-, FMR540-, FMR60-, FMR62-, FTC325-
Region/Country: Russia (Declaration of Conformity), Russia (TR CU)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05531MiscellaneousRusă -
Nivotester, Liquipoint, Nivotester FailSafe
Product Code: FTC325-, FTL325N-, FTL325P-, FTL375P-, FTW325-, FTL825-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TС RU D-DE.MU62.B.02537MiscellaneousRusă -
Liquiphant, Nivotester
Product Code: FTL825-
Region/Country: China
Approval Agency: NEPSI
Protection: [Ex ia Ga] IIC, [Ex iaD]Explosion ProtectionEngleză , Chineză -
Liquiphant, Nivotester
Product Code: FTL825-
Region/Country: Canada, USA
Approval Agency: FM
Category: [I//ZONE 2]
Protection: ANI, [AEx/Ex ia] IIC, [AEx/Ex ic] IIC, [Ex n] IIC, AISExplosion ProtectionEngleză -
Nivotester FailSafe
Product Code: FTL825-
Region/Country: China
Approval Agency: NEPSI
Protection: [Ex ia]Explosion ProtectionChineză -
Liquiphant, Nivotester
Product Code: FTL825-
Region/Country: Europe (ATEX)
Approval Agency: FM
Category: II (1) D, II (1) G
Protection: [Ex ia Da] IIIC, [Ex ia Ga] IICExplosion ProtectionEngleză -
Liquiphant, Nivotester
Product Code: FTL825-
Region/Country: Canada, USA
Approval Agency: CSA
Category: [I//ZONE 2]
Protection: [Ex ic Gc] IIC, [Ex ia Ga] IIC, [AEx ic Gc] IIC, [AEx ia Ga] IIC, ANI, AISExplosion ProtectionEngleză -
Liquiphant, Nivotester
Product Code: FTL825-
Region/Country: International (IECEx)
Approval Agency: FM
Protection: [Ex ia Da] IIIC, [Ex ia Ga] IICExplosion ProtectionEngleză -
Nivotester FailSafe
Product Code: FTL825-
Region/Country: Russia
Protection: [Ex ia Da] IIIC, [Ex ia Ga] IICExplosion ProtectionRusă -
Liquiphant, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85-
Region/Country: Switzerland
Approval Agency: SVTI
Approval Number: 302.014.18Overfill PreventionGermană -
Liquiphant, Liquiphant FailSafe, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85-
Region/Country: Germany
Approval Agency: TÜV
Approval Number: TÜV.ÜS3.18-056Overfill PreventionGermană , Engleză -
Liquiphant, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.11-507Overfill PreventionGermană -
Liquiphant, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85-
Region/Country: Germany
Approval Agency: DIBt
Approval Number: Z-65.40-508Overfill PreventionGermană -
Liquiphant, Nivotester
Product Code: FTL80-, FTL81-, FTL825-, FTL85-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)Germană , Engleză -
Nivotester
Product Code: FTL825-
Region/Country: International
Approval Agency: DNVGLMarineEngleză -
Nivotester
Product Code: FTL825-
Approval Agency: LRMarineEngleză -
Nivotester
Product Code: FTL825-
Approval Agency: ABSMarineEngleză -
Nivotester
Product Code: FTL825-
Approval Agency: ABSMarineEngleză -
Nivotester, Nivotester FailSafe
Product Code: FTL325N-, FTL325P-, FTL825-
Region/Country: International
Approval Agency: RM RSMarineRusă -
Nivotester
Product Code: FTL825-
Approval Agency: BVMarineEngleză -
Nivotester
Product Code: FTL825-
Approval Agency: LRMarineEngleză -
Liquiphant, Nivotester
Product Code: FTL825-
Region/Country: Canada, USA
Approval Agency: CSAOrdinary Location Product SafetyEngleză
Accesorii / Piese de schimb
-
-
Order code 71185026
Fuse set FTL825, T 3,15A/250V, 2pcs.
Design 5x20. Consists of: 2x fuse 250V. 2x fuse holder. Usage: FTL825.
-
Order code 52010132
Housing Field, R4 182x180x165, 5xM20, PC
Protection housing Minitec. Synthetic housing with transparent cover. Protection IP66. 4x22.5mm / 2x45mm. Usage: FTL825.
-