iTHERM ModuLine TM101
RTD or thermocouple temperature probe for direct installation in various industrial applications
Basic thermometers offer reliable temperature measurement performance with basic sensor technology, a standard extension neck and a fixed, non-replaceable insert for use in non-hazardous areas. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.
- F
- L
- E
- X
-
Produse de specialitate
- Conceput pentru aplicatii solicitante
Excelenţă tehnică
Simplitate
Variabil
Colecții FLEX | Excelenţă tehnică | Simplitate |
---|---|---|
Colecție Fundamental Îndepliniți-vă nevoile esențiale de măsurare |
Excelenţă tehnică
|
Simplitate
|
Selecţie Lean Gestionați-vă cu ușurință procesele de bază |
Excelenţă tehnică
|
Simplitate
|
Colecție Extended Optimizați-vă procesele cu tehnologii inovatoare |
Excelenţă tehnică
|
Simplitate
|
Colecție Xpert Stăpâniţi cele mai dificile aplicaţii |
Excelenţă tehnică
|
Simplitate
Variabil |
-
Specificaţii pe scurt
-
Accuracy
Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2 -
Response time
t90 around 17 s
depending on configuration -
Max. process pressure (static)
depending on the configuration
-
Operating temperature range
Basic PT100 TF:
-50 °C …200 °C
(-58 °F …392 °F)
Thermocouple:
Typ K up to 600 °C (1.112 °F) -
Max. immersion length on request
up to 1.000,0 mm (39'')
-
Selectare rapidă
Configurare individuală
-
Avantaje
Excellent value for money and fast global delivery
User-friendly product selection, smart design for easy maintenance
Wide range of process connections
Bluetooth® connectivity (optional)
-
Domeniu de aplicare
Wide range of applications
Measuring range: -50 to +650 °C (-58 to +1202 °F)
Pressure range: up to 50 bar (725 psi)
Protection class: up to IP68
For use in non-hazardous areas
Documente / Manuale / Software
-
iTHERM ModuLine TM101
Metric version with basic technology, non-replaceable insert for all
standard applicationsTechnical Information (TI) -
Modular thermometers
Operating Instructions
Universal modular thermometers with RTD or TC insert for industrial
applicationsOperating Instruction (BA) -
TRxx, TCxx, TS211, iTHERM TS111, TM211, TPx100, TSx310, TM1x1, TM411,
TM412
Thermometers and inserts
Ex nA IIC T6...T1 GcEx Safety Instructions (XA) -
Process RTD General purpose
Product Code: TM101-
Declaration Number: HE_01244_01.20
Manufacturer Specification: RoHSManufacturer DeclarationChineză -
Process TC Heavy duty, Process TC General purpose, Process TC Direct contact, Process RTD Hygienic, Process RTD Heavy duty, Process RTD General purpose, Process RTD Direct contact, Low cost RTD General purpose
Product Code: TM412-, TR10-, TR11-, TR12-, TR13-, TR15-, TR24-, TR25-, TR44-, TR45-, TR46-, TR47-, TR48-, TR61-, TR62-, TR63-, TR65-, TR66-, TR88-, TST40N-, TST41N-, TST434-, TM411-, TAF11-, TAF12D-, TAF12S-, TAF12T-, TAF16-, TC10-, TC12-, TC13-, TC15-, TC61-, TC62-, TC63-, TC65-, TC66-, TC88-, TEC420-, TM101-, TM111-, TM121-, TM131-, TM401-, TM402-
Declaration Number: EC_00136_02.16EU DeclarationGermană , Engleză
Accesorii / Piese de schimb
-
-
Order code 71367427
-
Order code 71182602
Spare parts kit sealing TA30A/TA30D
5x O-ring 3.69x1.78 5x 0-ring 74.7x2.75
-
Order code 71367414
-
Order code 71367420
-
Order code 71367425
-
Order code 71369768
O-Ring 71X3 silicone 70° Shore A
-
Order code 71438347
-
Order code TK40-
Compression Fitting TK40
Weld-in compression fitting with hygienic design. For applications in the food/ beverages and pharmaceutical industries.
-
Order code TA20AB-
Terminal Head TA20AB
Terminal head for temperature assemblies, simple execution, lid fixed by screws. Inner geometry acc. to DIN EN 50446.
-
Order code TA30A-
Terminal Head TA30A
Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).
-
Order code TA30EB-
Terminal Head TA30EB
Retainer for terminal block or head transmitter + optional display. Cover: low, threaded, optional window. Material: Aluminium. Coating: Polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...+150oC (housing). Protection: IP66/68, NEMA 4X (housing).
-
Order code TS111-
Insert iTHERM TS111
Replaceable. Metric version according DIN43735.
-
Order code TMT180-
iTEMP TMT180, Head Transmitter Pt100
Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.
-
Order code TMT71-
iTEMP TMT71, Transmitter 4-20mA
2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
-
Order code TMT72-
iTEMP TMT72, Transmitter HART
2-wire temperature transmitter. Single universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. Factory setup w/o additional specification:Pt100, 4-wire, 0...+100oC.
-
Order code DIENST-
Service
-
-
Predecesor